タイトル: | Reliability and validity of gait analysis by android-based smartphone. |
著者: | Nishiguchi, Shu Yamada, Minoru Nagai, Koutatsu Mori, Shuhei Kajiwara, Yuu Sonoda, Takuya Yoshimura, Kazuya Yoshitomi, Hiroyuki ![]() ![]() ![]() Ito, Hiromu ![]() Okamoto, Kazuya ![]() ![]() Ito, Tatsuaki Muto, Shinyo Ishihara, Tatsuya Aoyama, Tomoki ![]() ![]() ![]() |
著者名の別形: | 西口, 周 |
キーワード: | smartphones accelerometers gait analysis reliability validity |
発行日: | May-2012 |
出版者: | Mary Ann Liebert, Inc. |
誌名: | Telemedicine and e-health |
巻: | 18 |
号: | 4 |
開始ページ: | 292 |
終了ページ: | 296 |
抄録: | Abstract Smartphones are very common devices in daily life that have a built-in tri-axial accelerometer. Similar to previously developed accelerometers, smartphones can be used to assess gait patterns. However, few gait analyses have been performed using smartphones, and their reliability and validity have not been evaluated yet. The purpose of this study was to evaluate the reliability and validity of a smartphone accelerometer. Thirty healthy young adults participated in this study. They walked 20 m at their preferred speeds, and their trunk accelerations were measured using a smartphone and a tri-axial accelerometer that was secured over the L3 spinous process. We developed a gait analysis application and installed it in the smartphone to measure the acceleration. After signal processing, we calculated the gait parameters of each measurement terminal: peak frequency (PF), root mean square (RMS), autocorrelation peak (AC), and coefficient of variance (CV) of the acceleration peak intervals. Remarkable consistency was observed in the test-retest reliability of all the gait parameter results obtained by the smartphone (p<0.001). All the gait parameter results obtained by the smartphone showed statistically significant and considerable correlations with the same parameter results obtained by the tri-axial accelerometer (PF r=0.99, RMS r=0.89, AC r=0.85, CV r=0.82; p<0.01). Our study indicates that the smartphone with gait analysis application used in this study has the capacity to quantify gait parameters with a degree of accuracy that is comparable to that of the tri-axial accelerometer. |
著作権等: | This is a copy of an article published in the Telemedicine and e-health. © 2012 Mary Ann Liebert, Inc. "Telemedicine and e-Health" is available online at: http://www.liebertonline.com. |
URI: | http://hdl.handle.net/2433/156135 |
DOI(出版社版): | 10.1089/tmj.2011.0132 |
PubMed ID: | 22400972 |
出現コレクション: | 学術雑誌掲載論文等 |

このリポジトリに保管されているアイテムはすべて著作権により保護されています。