Downloads: 360
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
TASC.2011.2180295.pdf | 1.1 MB | Adobe PDF | View/Open |
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Amemiya, Naoyuki | en |
dc.contributor.author | Mizuta, Shingo | en |
dc.contributor.author | Nakamura, Taketsune | en |
dc.contributor.author | Ogitsu, Toru | en |
dc.contributor.author | Orikasa, Tomofumi | en |
dc.contributor.author | Kurusu, Tsutomu | en |
dc.contributor.author | Obana, Tetsuhiro | en |
dc.contributor.author | Noda, Koji | en |
dc.contributor.alternative | 雨宮, 尚之 | ja |
dc.date.accessioned | 2012-07-11T02:30:46Z | - |
dc.date.available | 2012-07-11T02:30:46Z | - |
dc.date.issued | 2012-06 | - |
dc.identifier.issn | 1051-8223 | - |
dc.identifier.uri | http://hdl.handle.net/2433/158278 | - |
dc.description.abstract | Magnetic field harmonics (multi-pole component of magnetic field) were measured in a 24-layer coil for a dipole magnet wound with NbTi round wires by using the surface winding technology (direct winding technology). The coil was wound layer by layer, and the magnetic field measurements were carried out by using rotating pick-up coil system, when the 4 layers, 10 layers, 16 layers, 20 layers, and 24 layers of the coil were wound. The measured magnetic field harmonics were compared with theoretical values. The error, which is the difference between the measured value and theoretical one, does not increase substantially with increasing number of wound layers when measured at the center of the coil. Larger errors measured near the coil end should have been caused by the position errors of wires, which was observed visually. | en |
dc.format.mimetype | application/pdf | - |
dc.language.iso | eng | - |
dc.publisher | IEEE | en |
dc.rights | © 2012 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. | en |
dc.rights | この論文は出版社版でありません。引用の際には出版社版をご確認ご利用ください。 | ja |
dc.rights | This is not the published version. Please cite only the published version. | en |
dc.subject | Accelerator magnets | en |
dc.subject | direct winding | en |
dc.subject | field harmonics | en |
dc.subject | surface winding | en |
dc.title | Measurements of Magnetic Field Harmonics in Superconductor Coil Wound by Surface Winding Technology | en |
dc.type | journal article | - |
dc.type.niitype | Journal Article | - |
dc.identifier.ncid | AA11946236 | - |
dc.identifier.jtitle | IEEE Transactions on Applied Superconductivity | en |
dc.identifier.volume | 22 | - |
dc.identifier.issue | 3 | - |
dc.relation.doi | 10.1109/TASC.2011.2180295 | - |
dc.textversion | author | - |
dc.identifier.artnum | 9000404 | - |
dcterms.accessRights | open access | - |
Appears in Collections: | Journal Articles |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.