ダウンロード数: 140

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
1.4891102.pdf1.77 MBAdobe PDF見る/開く
完全メタデータレコード
DCフィールド言語
dc.contributor.authorOhshima, S.en
dc.contributor.authorKobayashi, S.en
dc.contributor.authorYamamoto, S.en
dc.contributor.authorNagasaki, K.en
dc.contributor.authorMizuuchi, T.en
dc.contributor.authorKado, S.en
dc.contributor.authorOkada, H.en
dc.contributor.authorMinami, T.en
dc.contributor.authorLee, H. Y.en
dc.contributor.authorZang, L.en
dc.contributor.authorKenmochi, N.en
dc.contributor.authorKasajima, K.en
dc.contributor.authorOhtani, Y.en
dc.contributor.authorShi, N.en
dc.contributor.authorNagae, Y.en
dc.contributor.authorKonoshima, S.en
dc.contributor.authorSano, F.en
dc.contributor.alternative大島, 慎介ja
dc.date.accessioned2014-09-03T05:11:31Z-
dc.date.available2014-09-03T05:11:31Z-
dc.date.issued2014-11-
dc.identifier.issn0034-6748-
dc.identifier.urihttp://hdl.handle.net/2433/189550-
dc.description.abstractA fluctuation analysis technique using analytic signals is proposed. Analytic signals are suitable to characterize a single mode with time-dependent amplitude and frequency, such as an MHD mode observed in fusion plasmas since the technique can evaluate amplitude and frequency at a specific moment without limitations of temporal and frequency resolutions, which is problematic in Fourier-based analyses. Moreover, a concept of instantaneous phase difference is newly introduced, and error of the evaluated phase difference and its error reduction techniques using conditional/ensemble averaging are discussed. These techniques are applied to experimental data of the beam emission spectroscopic measurement in the Heliotron J device, which demonstrates that the technique can describe nonlinear evolution of MHD instabilities. This technique is widely applicable to other diagnostics having necessity to evaluate phase difference.en
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherAIP Publishingen
dc.rights© 2014 AIP Publishing LLCen
dc.titleHighly time-resolved evaluation technique of instantaneous amplitude and phase difference using analytic signals for multi-channel diagnosticsa)en
dc.typejournal article-
dc.type.niitypeJournal Article-
dc.identifier.ncidAA00817730-
dc.identifier.jtitleReview of Scientific Instrumentsen
dc.identifier.volume85-
dc.identifier.issue11-
dc.relation.doi10.1063/1.4891102-
dc.textversionpublisher-
dc.identifier.artnum11E814-
dc.identifier.pmid25430379-
dcterms.accessRightsopen access-
dc.identifier.pissn0034-6748-
dc.identifier.eissn1089-7623-
出現コレクション:学術雑誌掲載論文等

アイテムの簡略レコードを表示する

Export to RefWorks


出力フォーマット 


このリポジトリに保管されているアイテムはすべて著作権により保護されています。