タイトル: | Revising the existing Performance Indicator system for small water supply utilities in Japan |
著者: | Shinde, Victor Rana Hirayama, Nagahisa Mugita, Ai Itoh, Sadahiko ![]() ![]() ![]() |
著者名の別形: | 伊藤, 禎彦 |
キーワード: | benchmarking PDCA cycle Performance Indicators Principal Component Analysis small water utilities |
発行日: | Dec-2013 |
出版者: | Taylor & Francis Group |
誌名: | Urban Water Journal |
巻: | 10 |
号: | 6 |
開始ページ: | 377 |
終了ページ: | 393 |
抄録: | 97.5% of the water utilities in Japan serve less than 50, 000 customers, and are called small water utilities. The Performance Indicator system in Japan, used to evaluate the performance of various aspects of the supply system, currently has 137 items, which are too many in number for the small utilities to adopt because of resource and financial constraints. The objective of this study is to, thus, revise the existing PI system to arrive at a reduced, relevant and practical structure that provides enough information to rationally evaluate small water supply systems in Japan. Principal Component Analysis was used to reduce the dimensionality of the original data. The results suggest that only nine components, consisting of 33 items (called 9-cPIS), are sufficient for evaluating the small water utilities. The effectiveness of the 9-cPIS in benchmarking, evaluating business models, and the planning and management of the water utilities has been discussed further. |
著作権等: | The Version of Record of this manuscript has been published and is available in Urban Water Journal (2013) http://www.tandfonline.com/10.1080/1573062X.2012.739628. この論文は出版社版でありません。引用の際には出版社版をご確認ご利用ください。 This is not the published version. Please cite only the published version. |
URI: | http://hdl.handle.net/2433/193046 |
DOI(出版社版): | 10.1080/1573062X.2012.739628 |
出現コレクション: | 学術雑誌掲載論文等 |