タイトル: | Feasibility of tension braces using Cu-Al-Mn superelastic alloy bars |
著者: | Araki, Yoshikazu Maekawa, Nao Shrestha, Kshitij C. Yamakawa, Makoto Koetaka, Yuji ![]() ![]() ![]() Omori, Toshihiro Kainuma, Ryosuke |
著者名の別形: | 荒木, 慶一 |
キーワード: | Cu-Al-Mn superelastic alloy (SEA) shape memory alloy (SMA) tension-only brace steel frame shaking table test |
発行日: | 12-Feb-2014 |
出版者: | wiley |
誌名: | Structural Control and Health Monitoring |
巻: | 21 |
号: | 10 |
開始ページ: | 1304 |
終了ページ: | 1315 |
抄録: | This paper investigates the feasibility of tension braces using Cu–Al–Mn superelastic alloy bars as energy dissipating and self-centering elements for steel frames by performing 1/3 scale shaking table tests. The difficulty with conventional steel tension braces lies in pinching or significant deterioration of stiffness and strength under cyclic loading. When a steel frame with conventional tension braces is subjected to intense earthquakes, pinching may lead to a large residual drift and/or instability. To overcome the difficulty, this paper examines the effectiveness of Cu–Al–Mn superelastic alloy bars, facilitated by their large recovery strain, low material cost, and high machinability, as a partial replacement of steel bars in tension braces. In the shaking table tests, a 1/3 scaled 1-bay, 1-story steel frame with the present tension braces is subjected to quasi-static cyclic loading and dynamic harmonic ground motions of 6 Hz. Both the static and dynamic test results demonstrate the effectiveness of the present braces in avoiding pinching under the ductility ratio up to 3. The dynamic test results also demonstrate the capability of the present tension braces in reducing the peak response acceleration within the base shear capacity. To study the rate dependence of the frame response, further, time-history analyses are performed by using a SDOF model based on a uniaxial rate-independent model, calibrated with the quasi-static tests. A comparison of the analytical results with the dynamic test results demonstrates that the rate dependence of the frame response is negligible up to the loading frequency of 6 Hz. |
著作権等: | This is the peer reviewed version of the following article: Araki Y., Maekawa N., Shrestha K. C., Yamakawa M., Koetaka Y., Omori T. and Kainuma R. (2014), Feasibility of tension braces using Cu–Al–Mn superelastic alloy bars, Struct. Control Health Monit., 21: 1304–1315, which has been published in final form at http://dx.doi.org/10.1088/0964-1726/23/10/105027. This is not the published version. Please cite only the published version. この論文は出版社版でありません。引用の際には出版社版をご確認ご利用ください。 |
URI: | http://hdl.handle.net/2433/198603 |
DOI(出版社版): | 10.1002/stc.1644 |