ダウンロード数: 1011

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
j.knee.2015.02.019.pdf1.09 MBAdobe PDF見る/開く
完全メタデータレコード
DCフィールド言語
dc.contributor.authorIshikawa, Masahiroen
dc.contributor.authorKuriyama, Shinichien
dc.contributor.authorIto, Hiromuen
dc.contributor.authorFuru, Moritoshien
dc.contributor.authorNakamura, Shinichiroen
dc.contributor.authorMatsuda, Shuichien
dc.contributor.alternative石川, 正洋ja
dc.contributor.alternative松田, 秀一ja
dc.date.accessioned2015-11-30T01:20:03Z-
dc.date.available2015-11-30T01:20:03Z-
dc.date.issued2015-06-
dc.identifier.issn0968-0160-
dc.identifier.urihttp://hdl.handle.net/2433/202001-
dc.descriptionAvailable online 23 March 2015en
dc.description.abstract[Background]Kinematically aligned total knee arthroplasty (TKA) is of increasing interest because this method might improve postoperative patient satisfaction. In kinematic alignment the femoral component is implanted in a slightly more valgus and internally rotated position, and the tibial component is implanted in a slightly more varus and internally rotated position, than in mechanical alignment. However, the biomechanics of kinematically aligned TKA remain largely unknown. The aim of this study was to compare the kinematics and contact stresses of mechanically and kinematically aligned TKAs. [Methods]A musculoskeletal computer simulation was used to determine the effects of mechanically or kinematically aligned TKA. Knee kinematics were examined for mechanically aligned, kinematically aligned, and kinematically aligned outlier models. Patellofemoral and tibiofemoral contact forces were measured using finite element analysis. [Results]Greater femoral rollback and more external rotation of the femoral component were observed with kinematically aligned TKA than mechanically aligned TKA. However, patellofemoral and tibiofemoral contact stresses were increased in kinematically aligned TKA. [Conclusions]These findings suggest that kinematically aligned TKA produces near-normal knee kinematics, but that concerns for long-term outcome might arise because of high contact stressesen
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherElsevier B.V.en
dc.rights© 2015. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/en
dc.rightsThe full-text file will be made open to the public on 23 March 2016 in accordance with publisher's 'Terms and Conditions for Self-Archiving'.en
dc.rightsThis is not the published version. Please cite only the published version.en
dc.rightsこの論文は出版社版でありません。引用の際には出版社版をご確認ご利用ください。ja
dc.subjectTotal knee arthroplastyen
dc.subjectKinematically aligned TKAen
dc.subjectKnee kinematicsen
dc.subjectFinite element analysisen
dc.titleKinematic alignment produces near-normal knee motion but increases contact stress after total knee arthroplasty: A case study on a single implant design.en
dc.typejournal article-
dc.type.niitypeJournal Article-
dc.identifier.jtitleThe Kneeen
dc.identifier.volume22-
dc.identifier.issue3-
dc.identifier.spage206-
dc.identifier.epage212-
dc.relation.doi10.1016/j.knee.2015.02.019-
dc.textversionauthor-
dc.startdate.bitstreamsavailable2016-03-23-
dc.identifier.pmid25813759-
dcterms.accessRightsopen access-
出現コレクション:学術雑誌掲載論文等

アイテムの簡略レコードを表示する

Export to RefWorks


出力フォーマット 


このリポジトリに保管されているアイテムはすべて著作権により保護されています。