ダウンロード数: 412

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
jssc.201500444.pdf2.09 MBAdobe PDF見る/開く
完全メタデータレコード
DCフィールド言語
dc.contributor.authorZhu, Yangen
dc.contributor.authorMorisato, Keien
dc.contributor.authorHasegawa, Georgeen
dc.contributor.authorMoitra, Nirmalyaen
dc.contributor.authorKiyomura, Tsutomuen
dc.contributor.authorKurata, Hirokien
dc.contributor.authorKanamori, Kazuyoshien
dc.contributor.authorNakanishi, Kazukien
dc.contributor.alternative中西, 和樹ja
dc.date.accessioned2015-12-08T05:06:16Z-
dc.date.available2015-12-08T05:06:16Z-
dc.date.issued2015-08-
dc.identifier.issn1615-9314-
dc.identifier.urihttp://hdl.handle.net/2433/202103-
dc.descriptionArticle first published online: 15 JUL 2015en
dc.description.abstractThe optimization of a porous structure to ensure good separation performances is always a significant issue in high-performance liquid chromatography column design. Recently we reported the homogeneous embedment of Ag nanoparticles in periodic mesoporous silica monolith and the application of such Ag nanoparticles embedded silica monolith for the high-performance liquid chromatography separation of polyaromatic hydrocarbons. However, the separation performance remains to be improved and the retention mechanism as compared with the Ag ion high-performance liquid chromatography technique still needs to be clarified. In this research, Ag nanoparticles were introduced into a macro/mesoporous silica monolith with optimized pore parameters for high-performance liquid chromatography separations. Baseline separation of benzene, naphthalene, anthracene, and pyrene was achieved with the theoretical plate number for analyte naphthalene as 36, 000 m(-1). Its separation function was further extended to cis/trans isomers of aromatic compounds where cis/trans stilbenes were chosen as a benchmark. Good separation of cis/trans-stilbene with separation factor as 7 and theoretical plate number as 76, 000 m(-1) for cis-stilbene was obtained. The trans isomer, however, is retained more strongly, which contradicts the long- established retention rule of Ag ion chromatography. Such behavior of Ag nanoparticles embedded in a silica column can be attributed to the differences in the molecular geometric configuration of cis/trans stilbenes.en
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherwileyen
dc.rightsThis is the peer reviewed version of the following article: Zhu, Y., Morisato, K., Hasegawa, G., Moitra, N., Kiyomura, T., Kurata, H., Kanamori, K. and Nakanishi, K. (2015), High-performance liquid chromatography separation of unsaturated organic compounds by a monolithic silica column embedded with silver nanoparticles. J. Sep. Science, 38: 2841–2847, which has been published in final form at http://dx.doi.org/10.1002/jssc.201500444. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Self-Archiving.en
dc.rightsThe full-text file will be made open to the public on 15 JUL 2016 in accordance with publisher's 'Terms and Conditions for Self-Archiving'.en
dc.rightsThis is not the published version. Please cite only the published version.en
dc.rightsこの論文は出版社版でありません。引用の際には出版社版をご確認ご利用ください。ja
dc.subjectcis/trans Isomersen
dc.subjectHigh-performance liquid chromatographyen
dc.subjectMonolithic silica columnsen
dc.subjectPolyaromatic hydrocarbonsen
dc.subjectSilver nanoparticlesen
dc.titleHigh-performance liquid chromatography separation of unsaturated organic compounds by a monolithic silica column embedded with silver nanoparticles.en
dc.typejournal article-
dc.type.niitypeJournal Article-
dc.identifier.jtitleJournal of separation scienceen
dc.identifier.volume38-
dc.identifier.issue16-
dc.identifier.spage2841-
dc.identifier.epage2847-
dc.relation.doi10.1002/jssc.201500444-
dc.textversionauthor-
dc.startdate.bitstreamsavailable2016-07-15-
dc.identifier.pmid26097062-
dcterms.accessRightsopen access-
出現コレクション:学術雑誌掲載論文等

アイテムの簡略レコードを表示する

Export to RefWorks


出力フォーマット 


このリポジトリに保管されているアイテムはすべて著作権により保護されています。