タイトル: Early clinical experience utilizing scintillator with optical fiber (SOF) detector in clinical boron neutron capture therapy: its issues and solutions
著者: Ishikawa, Masayori
Yamamoto, Tetsuya
Matsumura, Akira
Hiratsuka, Junichi
Miyatake, Shin-Ichi
Kato, Itsuro
Sakurai, Yoshinori  kyouindb  KAKEN_id  orcid https://orcid.org/0000-0001-9404-4255 (unconfirmed)
Kumada, Hiroaki
Shrestha, Shubhechha J.
Ono, Koji
著者名の別形: 石川, 正純
櫻井, 良憲
小野, 公二
キーワード: SOF detector
Ultra-miniature detector
Thermal neutron monitor
Clinical trial
BNCT
発行日: 9-Aug-2016
出版者: Springer Nature
誌名: Radiation Oncology
巻: 11
論文番号: 105
抄録: [Background] Real-time measurement of thermal neutrons in the tumor region is essential for proper evaluation of the absorbed dose in boron neutron capture therapy (BNCT) treatment. The gold wire activation method has been routinely used to measure the neutron flux distribution in BNCT irradiation, but a real-time measurement using gold wire is not possible. To overcome this issue, the scintillator with optical fiber (SOF) detector has been developed. The purpose of this study is to demonstrate the feasibility of the SOF detector as a real-time thermal neutron monitor in clinical BNCT treatment and also to report issues in the use of SOF detectors in clinical practice and their solutions. [Material and methods] Clinical measurements using the SOF detector were carried out in 16 BNCT clinical trial patients from December 2002 until end of 2006 at the Japanese Atomic Energy Agency (JAEA) and Kyoto University Research Reactor Institute (KURRI). [Results] The SOF detector worked effectively as a real-time thermal neutron monitor. The neutron fluence obtained by the gold wire activation method was found to differ from that obtained by the SOF detector. The neutron fluence obtained by the SOF detector was in better agreement with the expected fluence than with gold wire activation. The estimation error for the SOF detector was small in comparison to the gold wire measurement. In addition, real-time monitoring suggested that the neutron flux distribution and intensity at the region of interest (ROI) may vary due to the reactor condition, patient motion and dislocation of the SOF detector. [Conclusion] Clinical measurements using the SOF detector to measure thermal neutron flux during BNCT confirmed that SOF detectors are effective as a real-time thermal neutron monitor. To minimize the estimation error due to the displacement of the SOF probe during treatment, a loop-type SOF probe was developed.
著作権等: © 2016 The Author(s). Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
URI: http://hdl.handle.net/2433/225103
DOI(出版社版): 10.1186/s13014-016-0680-0
PubMed ID: 27506665
出現コレクション:学術雑誌掲載論文等

アイテムの詳細レコードを表示する

Export to RefWorks


出力フォーマット 


このリポジトリに保管されているアイテムはすべて著作権により保護されています。