このアイテムのアクセス数: 206
このアイテムのファイル:
ファイル | 記述 | サイズ | フォーマット | |
---|---|---|---|---|
0004-637X_810_1_28.pdf | 3.08 MB | Adobe PDF | 見る/開く |
タイトル: | AN ELECTRON-TRACKING COMPTON TELESCOPE FOR A SURVEY OF THE DEEP UNIVERSE BY MeV GAMMA-RAYS |
著者: | Tanimori, T. Kubo, H. Takada, A. Iwaki, S. Komura, S. Kurosawa, S. Matsuoka, Y. Miuchi, K. Miyamoto, S. Mizumoto, T. Mizumura, Y. Nakamura, K. Nakamura, S. Oda, M. Parker, J. D. Sawano, T. Sonoda, S. Takemura, T. Tomono, D. Ueno, K. |
著者名の別形: | 谷森, 達 窪, 秀利 高田, 淳史 岩城, 智 古村, 翔太郎 松岡, 佳大 宮本, 奨平 水本, 哲矢 水村, 好貴 中村, 輝石 中村, 優太 小田, 真 澤野, 達哉 園田, 真也 竹村, 泰斗 友野, 大 上野, 一樹 |
キーワード: | gamma-ray burst: general instrumentation: detectors nuclear reactions, nucleosynthesis, abundances supernovae: general techniques: imaging spectroscopy |
発行日: | 1-Sep-2015 |
出版者: | IOP Publishing American Astronomical Society |
誌名: | The Astrophysical Journal |
巻: | 810 |
号: | 1 |
論文番号: | 28 |
抄録: | Photon imaging for MeV gammas has serious difficulties due to huge backgrounds and unclearness in images, which originate from incompleteness in determining the physical parameters of Compton scattering in detection, e.g., lack of the directional information of the recoil electrons. The recent major mission/instrument in the MeV band, Compton Gamma Ray Observatory/COMPTEL, which was Compton Camera (CC), detected a mere ∼30 persistent sources. It is in stark contrast with the ∼2000 sources in the GeV band. Here we report the performance of an Electron-Tracking Compton Camera (ETCC), and prove that it has a good potential to break through this stagnation in MeV gamma-ray astronomy. The ETCC provides all the parameters of Compton-scattering by measuring 3D recoil electron tracks; then the Scatter Plane Deviation (SPD) lost in CCs is recovered. The energy loss rate (dE/dx), which CCs cannot measure, is also obtained, and is found to be helpful to reduce the background under conditions similar to those in space. Accordingly, the significance in gamma detection is improved severalfold. On the other hand, SPD is essential to determine the point-spread function (PSF) quantitatively. The SPD resolution is improved close to the theoretical limit for multiple scattering of recoil electrons. With such a well-determined PSF, we demonstrate for the first time that it is possible to provide reliable sensitivity in Compton imaging without utilizing an optimization algorithm. As such, this study highlights the fundamental weak-points of CCs. In contrast we demonstrate the possibility of ETCC reaching the sensitivity below 1 × 10(-12) erg cm(-2) s(-1) at 1 MeV. |
著作権等: | © 2015. The American Astronomical Society. All rights reserved. |
URI: | http://hdl.handle.net/2433/230142 |
DOI(出版社版): | 10.1088/0004-637X/810/1/28 |
出現コレクション: | 学術雑誌掲載論文等 |

このリポジトリに保管されているアイテムはすべて著作権により保護されています。