ダウンロード数: 327

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
nbm.3774.pdf2.17 MBAdobe PDF見る/開く
タイトル: Clinical evaluation of time-of-flight MR angiography with sparse undersampling and iterative reconstruction for cerebral aneurysms
著者: Fushimi, Yasutaka  kyouindb  KAKEN_id  orcid https://orcid.org/0000-0002-1982-3168 (unconfirmed)
Okada, Tomohisa  KAKEN_id  orcid https://orcid.org/0000-0003-2312-5677 (unconfirmed)
Kikuchi, Takayuki  kyouindb  KAKEN_id
Yamamoto, Akira  KAKEN_id  orcid https://orcid.org/0000-0002-8894-3622 (unconfirmed)
Okada, Tsutomu
Yamamoto, Takayuki
Schmidt, Michaela
Yoshida, Kazumichi  KAKEN_id  orcid https://orcid.org/0000-0002-8898-079X (unconfirmed)
Miyamoto, Susumu
Togashi, Kaori
著者名の別形: 伏見, 育崇
岡田, 知久
菊池, 隆幸
山本, 憲
岡田, 務
吉田, 和道
宮本, 享
富樫, かおり
キーワード: cerebral aneurysm
compressed sensing
parallel imaging
time‐of‐flight MR angiography
発行日: Nov-2017
出版者: Wiley
誌名: NMR in biomedicine
巻: 30
号: 11
論文番号: e3774
抄録: Compressed sensing (CS) MRI has just been introduced to research areas as an innovative approach to accelerate MRI. CS is expected to achieve higher k‐space undersampling by exploiting the underlying sparsity in an appropriate transform domain. MR angiography (MRA) provides high spatial resolution information on arteries; however, a relatively long acquisition time is necessary to cover a wide volume. Reduction of acquisition time by CS for time‐of‐flight (TOF) MR angiography (Sparse‐TOF) is beneficial in clinical examinations; therefore, the clinical validity of Sparse‐TOF needs to be investigated. The aim of this study was to compare the diagnostic capability of TOF MRA between parallel imaging (PI)‐TOF with an acceleration factor of 3 (annotated as 3×) and Sparse‐TOF (3× and 5×) in patients with cerebral aneurysms. PI‐TOF (3×) and Sparse‐TOF (3× and 5×) imaging were performed in 20 patients using a 3 T MRI system. Aneurysms in PI‐TOF (3×) and Sparse‐TOF (3× and 5×) were blindly rated as visible or scarcely visible by neuroradiologists. The neck, height and width of aneurysms were also measured. Twenty‐six aneurysms were visualized and rated as visible in PI‐TOF (3×) and Sparse‐TOF (3× and 5×), with excellent agreement between two raters. No significant differences were found in measured neck, height or width of aneurysms among them. Sparse‐TOF (3× and 5×) were acquired and reconstructed within 6 min, and cerebral aneurysms were visible in both of them with equivalent quality to PI‐TOF (3×). Sparse‐TOF (5×) is a good alternative to PI‐TOF (3×) to visualize cerebral aneurysms.
著作権等: This is the peer reviewed version of the following article: [Yasutaka Fushimi etc. Clinical evaluation of time‐of‐flight MR angiography with sparse undersampling and iterative reconstruction for cerebral aneurysms. NMR in biomedicine, 30(11) e3774], which has been published in final form at https://doi.org/10.1002/nbm.3774. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions.
The full-text file will be made open to the public on 16 October 2018 in accordance with publisher's 'Terms and Conditions for Self-Archiving'.