ダウンロード数: 67

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
j.anucene.2019.05.013.pdf739.38 kBAdobe PDF見る/開く
完全メタデータレコード
DCフィールド言語
dc.contributor.authorYamamoto, Toshihiroen
dc.contributor.authorSakamoto, Hirokien
dc.contributor.alternative山本, 俊弘ja
dc.date.accessioned2019-05-20T00:40:53Z-
dc.date.available2019-05-20T00:40:53Z-
dc.date.issued2019-11-
dc.identifier.issn0306-4549-
dc.identifier.urihttp://hdl.handle.net/2433/241540-
dc.description.abstractA new Monte Carlo method is developed to calculate the sensitivity coefficients of the α-eigenvalue (the time decay constant) and the γ-eigenvalue (the spatial decay constant in an exponential experiment) with respect to nuclear data. A method that was previously developed for the sensitivity analyses of the α-eigenvalue, which is not based on the normal k-α algorithm, is not applicable to the γ-eigenvalue due to its inability to obtain a converged source distribution. Then, a two-step method in which two sensitivity coefficients are separately calculated using the k-α or k-γ algorithm and the differential operator sampling method is newly developed. The sensitivity coefficient of the α- or γ-eigenvalue is represented by the ratio of the two sensitivity coefficients. Some numerical tests for three-energy group problems are performed using the new method. The sensitivity coefficients that are obtained by the new method are verified by comparing them to the solutions of deterministic transport calculations or to the approximate results that are obtained from the direct perturbations of the cross-sections.en
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherElsevier BVen
dc.rights© 2019. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/.en
dc.rightsThe full-text file will be made open to the public on 1 November 2021 in accordance with publisher's 'Terms and Conditions for Self-Archiving'.en
dc.rightsこの論文は出版社版でありません。引用の際には出版社版をご確認ご利用ください。ja
dc.rightsThis is not the published version. Please cite only the published version.en
dc.subjectAlpha-eigenvalueen
dc.subjectGamma-eigenvalueen
dc.subjectMonte Carloen
dc.subjectSensitivity analysisen
dc.subjectDifferential operatoren
dc.titleTwo-step Monte Carlo sensitivity analysis of alpha- and gamma-eigenvalues with the differential operator sampling methoden
dc.typejournal article-
dc.type.niitypeJournal Article-
dc.identifier.jtitleAnnals of Nuclear Energyen
dc.identifier.volume133-
dc.identifier.spage100-
dc.identifier.epage109-
dc.relation.doi10.1016/j.anucene.2019.05.013-
dc.textversionauthor-
dc.addressInstitute for Integrated Radiation and Nuclear Science, Kyoto Universityen
dc.addressRadiation Dose Analysis and Evaluation Network, Tokyoen
dcterms.accessRightsopen access-
datacite.date.available2021-11-01-
出現コレクション:学術雑誌掲載論文等

アイテムの簡略レコードを表示する

Export to RefWorks


出力フォーマット 


このリポジトリに保管されているアイテムはすべて著作権により保護されています。