タイトル: | Selective Isotope CT Imaging Based on Nuclear Resonance Fluorescence Transmission Method |
著者: | Ali, Khaled Ohgaki, Hideaki https://orcid.org/0000-0002-3553-4091 (unconfirmed) Zen, Heishun https://orcid.org/0000-0002-2719-6985 (unconfirmed) Kii, Toshiteru Hayakawa, Takehito Shizuma, Toshiyuki Toyokawa, Hiroyuki Taira, Yoshitaka Iancu, Violeta Turturica, Gabriel Ur, Calin Alexandru Fujimoto, Masaki Katoh, Masahiro |
著者名の別形: | 大垣, 英明 全, 炳俊 紀井, 俊輝 早川, 岳人 静間, 俊行 豊川, 弘之 平, 義隆 藤本, 將輝 加藤, 政博 |
キーワード: | Computed tomography (CT) isotope distribution laser Compton scattering (LCS) gamma-ray beam nuclear resonance fluorescence (NRF) |
発行日: | Aug-2020 |
出版者: | Institute of Electrical and Electronics Engineers (IEEE) |
誌名: | IEEE Transactions on Nuclear Science |
巻: | 67 |
号: | 8 |
開始ページ: | 1976 |
終了ページ: | 1984 |
抄録: | The isotope selectivity of computed tomography (CT) imaging based on nuclear resonance fluorescence (NRF) transmission method using a quasi-monochromatic laser Compton scattering (LCS) gamma-ray beam in the MeV region was demonstrated at the Ultra Violet Synchrotron Orbital Radiation–III (UVSOR-III) Synchrotron Radiation Facility (Institute of Molecular Science, National Institute of Natural Science) for two enriched lead isotope rods ( 206 Pb and 208 Pb) implanted in an aluminum cylinder. Since these two rods show the same gamma-ray attenuation in atomic processes, it is impossible to differentiate between them using a standard Gamma-CT technique based on atomic attenuation of gamma rays. The LCS gamma-ray beam had a maximum energy of 5.528 MeV and an intensity of approximately 5.5 photons/s/eV at the resonance energy ( Jπ=1− at 5.512 MeV in 208 Pb). A lead collimator with a hole diameter of 1 mm was used to define the size of the LCS gamma-ray beam at the CT target. The CT image of the 208 Pb rod was selectively obtained with a 2-mm pixel size resolution, which was determined by the horizontal step size of the CT stage. |
著作権等: | This work is licensed under a Creative Commons Attribution 4.0 License. Formore information, see https://creativecommons.org/licenses/by/4.0/ |
URI: | http://hdl.handle.net/2433/254063 |
DOI(出版社版): | 10.1109/tns.2020.3004565 |
出現コレクション: | 学術雑誌掲載論文等 |
このリポジトリに保管されているアイテムはすべて著作権により保護されています。