このアイテムのアクセス数: 121

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
s13014-021-01827-0.pdf2.7 MBAdobe PDF見る/開く
タイトル: Geometric and dosimetric impact of 3D generative adversarial network-based metal artifact reduction algorithm on VMAT and IMPT for the head and neck region
著者: Nakamura, Mitsuhiro  kyouindb  KAKEN_id
Nakao, Megumi  kyouindb  KAKEN_id  orcid https://orcid.org/0000-0002-5508-4366 (unconfirmed)
Imanishi, Keiho
Hirashima, Hideaki  kyouindb  KAKEN_id  orcid https://orcid.org/0000-0003-1548-1970 (unconfirmed)
Tsuruta, Yusuke
著者名の別形: 中村, 光宏
中尾, 恵
平島, 英明
鶴田, 裕輔
キーワード: 3D GAN
Metal artifact reduction
VMAT and IMPT
Head and neck cancer
発行日: 2021
出版者: Springer Nature
BMC
誌名: Radiation Oncology
巻: 16
論文番号: 96
抄録: [Background] We investigated the geometric and dosimetric impact of three-dimensional (3D) generative adversarial network (GAN)-based metal artifact reduction (MAR) algorithms on volumetric-modulated arc therapy (VMAT) and intensity-modulated proton therapy (IMPT) for the head and neck region, based on artifact-free computed tomography (CT) volumes with dental fillings. [Methods] Thirteen metal-free CT volumes of the head and neck regions were obtained from The Cancer Imaging Archive. To simulate metal artifacts on CT volumes, we defined 3D regions of the teeth for pseudo-dental fillings from the metal-free CT volumes. HU values of 4000 HU were assigned to the selected teeth region of interest. Two different CT volumes, one with four (m4) and the other with eight (m8) pseudo-dental fillings, were generated for each case. These CT volumes were used as the Reference. CT volumes with metal artifacts were then generated from the Reference CT volumes (Artifacts). On the Artifacts CT volumes, metal artifacts were manually corrected for using the water density override method with a value of 1.0 g/cm³ (Water). By contrast, the CT volumes with reduced metal artifacts using 3D GAN model extension of CycleGAN were also generated (GAN-MAR). The structural similarity (SSIM) index within the planning target volume was calculated as quantitative error metric between the Reference CT volumes and the other volumes. After creating VMAT and IMPT plans on the Reference CT volumes, the reference plans were recalculated for the remaining CT volumes. [Results] The time required to generate a single GAN-MAR CT volume was approximately 30 s. The median SSIMs were lower in the m8 group than those in the m4 group, and ANOVA showed a significant difference in the SSIM for the m8 group (p < 0.05). Although the median differences in D₉₈%, D₅₀% and D₂% were larger in the m8 group than the m4 group, those from the reference plans were within 3% for VMAT and 1% for IMPT. [Conclusions] The GAN-MAR CT volumes generated in a short time were closer to the Reference CT volumes than the Water and Artifacts CT volumes. The observed dosimetric differences compared to the reference plan were clinically acceptable.
著作権等: © The Author(s) 2021.
This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.
URI: http://hdl.handle.net/2433/276791
DOI(出版社版): 10.1186/s13014-021-01827-0
PubMed ID: 34092240
出現コレクション:学術雑誌掲載論文等

アイテムの詳細レコードを表示する

Export to RefWorks


出力フォーマット 


このアイテムは次のライセンスが設定されています: クリエイティブ・コモンズ・ライセンス Creative Commons