このアイテムのアクセス数: 65

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
GOX.0000000000003991.pdf1.04 MBAdobe PDF見る/開く
タイトル: Fingerstall-type tissue oximetry reduced anxiety of nurses in postoperative nursing monitoring of free flaps
著者: Tsuge, Itaru  kyouindb  KAKEN_id
Yamanaka, Hiroki  kyouindb  KAKEN_id  orcid https://orcid.org/0000-0002-1136-4139 (unconfirmed)
Katsube, Motoki  kyouindb  KAKEN_id  orcid https://orcid.org/0000-0001-7711-2439 (unconfirmed)
Sakamoto, Michiharu  KAKEN_id  orcid https://orcid.org/0000-0002-0024-6807 (unconfirmed)
Saito, Susumu  kyouindb  KAKEN_id
Morimoto, Naoki  kyouindb  KAKEN_id  orcid https://orcid.org/0000-0002-0712-3172 (unconfirmed)
著者名の別形: 津下, 到
山中, 浩気
勝部, 元紀
坂本, 道治
齊藤, 晋
森本, 尚樹
発行日: Dec-2021
出版者: Wolters Kluwer Health
The American Society of Plastic Surgeons
誌名: Plastic and Reconstructive Surgery - Global Open
巻: 9
号: 12
論文番号: e3991
抄録: Background: Postoperative free flap monitoring is essential for immediately detecting obstruction of anastomosed vessels with successive recovery surgery for salvaging flaps. We performed postoperative nursing monitoring using handheld Doppler sonography, but nurses reported feeling anxious with this approach and demanded a clear-cut evaluation method. Therefore, we implemented monitoring with the fingerstall-type tissue oximeter Toccare, a noninvasive device that enables easy flap checking by simply touching the flap with a probe. Method: Handheld Doppler was used for nursing monitoring from April to October 2020, with anxiety associated with its use reported. We collected information via an anonymous questionnaire to determine the reason for the anxiety. Toccare was subsequently applied for postoperative free flap monitoring by nurses. The protocol involved measuring tissue oxygen saturation by touching the flap with a Toccare probe every 4 hours from 24 to 100 hours postoperatively. Seven months later, a second anonymous questionnaire was conducted, and results were compared. Result: Free deep inferior epigastric artery perforator flaps and anterolateral thigh flaps (n = 5 each) were included. The average tissue oxygen saturation values in the deep inferior epigastric artery perforator and anterolateral thigh flaps were 52.0% and 52.4%, respectively. According to the second questionnaire about Toccare, 7% felt anxious, 62% felt slightly anxious, and 31% did not feel anxious. Toccare was preferred by 89% of nurses who had used both methods. Conclusions: Flap monitoring using Toccare reduced nurses’ anxiety. A numerical evaluation method with easy handling and clear doctor call criteria is essential for low-anxiety nursing monitoring.
著作権等: Copyright © 2021 The Authors. Published by Wolters Kluwer Health, Inc. on behalf of The American Society of Plastic Surgeons.
This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
URI: http://hdl.handle.net/2433/277434
DOI(出版社版): 10.1097/GOX.0000000000003991
PubMed ID: 34938644
出現コレクション:学術雑誌掲載論文等

アイテムの詳細レコードを表示する

Export to RefWorks


出力フォーマット 


このアイテムは次のライセンスが設定されています: クリエイティブ・コモンズ・ライセンス Creative Commons