タイトル: Size-exclusion chromatography–small-angle neutron scattering system optimized for an instrument with medium neutron flux
著者: Morishima, Ken
Inoue, Rintaro  kyouindb  KAKEN_id
Nakagawa, Tatsuo
Shimizu, Masahiro
Sakamoto, Ritsuki
Oda, Tatsuro
Mayumi, Koichi
Sugiyama, Masaaki
著者名の別形: 守島, 健
井上, 倫太郎
清水, 将裕
杉山, 正明
キーワード: size-exclusion chromatography–small-angle neutron scattering
SEC–SANS
inverse contrast matching
neutron flux
biomacromolecules.
発行日: Apr-2025
出版者: International Union of Crystallography (IUCr)
誌名: Journal of Applied Crystallography
巻: 58
号: 2
開始ページ: 595
終了ページ: 602
抄録: Biomacromolecular solutions inevitably contain impurities in addition to the target biomacromolecules. This has been a major obstacle to achieving highprecision solution scattering measurements. To overcome this problem, smallangle X-ray scattering (SAXS) coupled with size-exclusion chromatography (SEC-SAXS) has been developed. This method involves injecting the solution eluted by SEC directly into a measurement cell and conducting SAXS measurements during the elution of the target biomacromolecule. This technique has resulted in a paradigm shift in biomacromolecule solution scattering. Currently, the application of the SEC–SAXS system to small-angle neutron scattering (SANS) is being advanced. However, since the target biomacromolecules in the sample solution are not only purified but also diluted by SEC and pass through the sample cell in a short time, this method is being implemented in SANS instruments at high neutron flux. Here, we developed a new type of SEC–SANS system that can operate effectively with a SANS instrument at medium neutron flux. Its key innovation is the design and optimization of a dedicated flow path that allows for the storage of only the target biomolecules eluted from SEC in the sample cell. This innovation enables long-duration measurements, termed the ‘stopping mode’, for SEC samples. Consequently, this method allows for acquiring high-precision solution scattering data for target biomacromolecules, enabling SEC–SANS measurements even with SANS instruments at medium neutron flux.
著作権等: This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.
URI: http://hdl.handle.net/2433/292643
DOI(出版社版): 10.1107/s1600576725000779
PubMed ID: 40170965
出現コレクション:学術雑誌掲載論文等

アイテムの詳細レコードを表示する

Export to RefWorks


出力フォーマット 


このアイテムは次のライセンスが設定されています: クリエイティブ・コモンズ・ライセンス Creative Commons