タイトル: Comparison study of quantitative susceptibility mapping with GRAPPA and wave-CAIPI: reproducibility, consistency, and microbleeds detection
著者: Sakurama, Azusa
Fushimi, Yasutaka
Nakajima, Satoshi
Sakata, Akihiko
Okuchi, Sachi
Yamamoto, Takayuki
Otani, Sayo
Wicaksono, Krishna Pandu
Ikeda, Satoshi
Ito, Shuichi
Maki, Takakuni
Liu, Wei
Nakamoto, Yuji
キーワード: Quantitative susceptibility mapping
Wave-CAIPI
Generalized autocalibrating partially parallel acquisition
Microbleeds
発行日: Mar-2025
出版者: Springer Nature
誌名: Japanese journal of radiology
巻: 43
号: 3
開始ページ: 379
終了ページ: 388
抄録: [Purpose] We compared quantitative susceptibility mapping (QSM) with wave-CAIPI 9 × (QSM_WC9 ×) with reference standard QSM with GRAPPA 2 × (QSM_G2 ×) in two MR scanners. We also compared detectability of microbleeds in both QSMs to demonstrate clinical feasibility of both QSMs. [Materials and methods] This prospective study was approved by the institutional review board and written informed consent was obtained from each subject. Healthy subjects were recruited to evaluate intra-scanner reproducibility, inter-scanner consistency, and inter-sequence consistency of QSM_G2 × and QSM_WC9 × at 2 MR scanners. Susceptibility values measured with volume of interests (VOIs) were evaluated. Patients who were requested for susceptibility weighted imaging were also recruited in this study to measure microbleeds on QSM_G2 × and QSM_WC9 × . The number of microbleeds was compared between two QSMs. [Results] Total 55 healthy subjects (male 34, female 21, 38.3 years [23-79]) were included in this study. We investigated reproducibility and consistency of QSM_WC9 × by comparing reference standard QSM_G2 × in two MR scanners in this study, and high correlation (ρ, 0.93-0.97) and high intraclass correlation coefficient (ICC) (0.97-0.99) were obtained. Sixty patients (male 30, female 30; age, 55.4 years [21-85]) were finally enrolled in this prospective study. The ICC of the detected number of microbleeds between QSM_G2 × and QSM_WC9 × was 0.99 (0.98-0.99). [Conclusion] QSM_WC9 × and reference standard QSM_G2 × in two MR scanners showed good reproducibility and consistency in estimating magnetic susceptibilities. QSM_WC9 × and QSM_G2 × were also comparable in terms of microbleeds detection with good agreement of raters and high ICC.
著作権等: © The Author(s) 2024
This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.
URI: http://hdl.handle.net/2433/292950
DOI(出版社版): 10.1007/s11604-024-01683-4
PubMed ID: 39467931
出現コレクション:学術雑誌掲載論文等

アイテムの詳細レコードを表示する

Export to RefWorks


出力フォーマット 


このアイテムは次のライセンスが設定されています: クリエイティブ・コモンズ・ライセンス Creative Commons