タイトル: <Note>Combustibility of China Fir Wood Treated with Standard Fire Retardants
著者: Su, Wen-Yu
ISHIHARA, Shigehisa
TSAI, Cing-Mu
キーワード: China fir
Combustibility
Ignition
Smoke
After-flame
発行日: 30-Sep-1994
出版者: Wood Research Institute, Kyoto University
誌名: Wood research : bulletin of the Wood Research Institute Kyoto University
巻: 81
開始ページ: 34
終了ページ: 49
抄録: Test specimens were prepared from China fir (Cunninghamia lanceolata Hook), and impregnated with five fire retardant chemicals listed in Chinese National Standards (CNS). The treated specimens were tested for their combustibility according to CNS 6532 to measure the time required for the temperature of the exhausting air to exceed the standard referential curve, heat generation, factor of smoke, time of after-flame, and occurrence of cracks of the test. Comparison of the results demonstrated that three chemicals could meet requirements in the standard.
記述: この論文は国立情報学研究所の学術雑誌公開支援事業により電子化されました。