Access count of this item: 901
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
j.compscitech.2008.08.032.pdf | 1.06 MB | Adobe PDF | View/Open |
Title: | Effect of fiber array irregularities on microscopic interfacial normal stress states of transversely loaded UD-CFRP from viewpoint of failure initiation |
Authors: | Hojo, Masaki ![]() Mizuno, Masaaki Hobbiebrunken, Thomas Adachi, Taiji ![]() ![]() ![]() Tanaka, Mototsugu Ha, Sung Kyu |
Author's alias: | 北條, 正樹 |
Keywords: | B. Debonding C. Finite element analysis (FEA) C. Residual stress C. Transverse cracking Micromechanics |
Issue Date: | Sep-2009 |
Publisher: | Elsevier |
Journal title: | Composites Science and Technology |
Volume: | 69 |
Issue: | 11-12 |
Start page: | 1726 |
End page: | 1734 |
Abstract: | A detailed investigation has been carried out to determine the effect of local fiber array irregularities and controlling fiber distribution parameters on microscopic interfacial normal stress states for transversely-loaded unidirectional carbon fiber (CF)/epoxy composites. Linear elastic finite element analyses were carried out for two-dimensional image-based models composed of about 70 fibers. The relationship between the geometrical distribution of two adjacent fibers and the interfacial normal stresses (INSs) is investigated for all fibers in different image-based models. Three boundary conditions for loading were selected: Case A involved cooling from the curing temperature (the difference in temperature was -155 K); Case B involved transverse loading of 75 MPa chosen as an example of macroscopic transverse fracture strength; and Case C involved both cooling from the curing temperature and transverse loading of 75 MPa. High compressive INSs due to the difference in the coefficients of thermal expansion are observed at the location of the shortest interfiber distance for Case A (cooling). High tensile INSs are observed at the location of the shortest interfiber distance and where the fiber alignment angle to the loading direction is small for Case B (loading). For Case C (cooling and loading), the high thermal residual compressive INSs and the high mechanical tensile INSs compensate each other, and the INSs at a short interfiber distance are much lower than those for Case B. These results clearly indicate the importance of the contribution of the thermal residual stresses to the transverse tensile failure initiation of CF/epoxy laminates. |
Rights: | c 2008 Elsevier Ltd. All rights reserved. This is not the published version. Please cite only the published version. この論文は出版社版でありません。引用の際には出版社版をご確認ご利用ください。 |
URI: | http://hdl.handle.net/2433/80168 |
DOI(Published Version): | 10.1016/j.compscitech.2008.08.032 |
Related Link: | http://www.scopus.com/inward/record.url?eid=2-s2.0-67649126253&partnerID=40 |
Appears in Collections: | Journal Articles |

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.