ダウンロード数: 403

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
RLI.0000000000000159.pdf2.05 MBAdobe PDF見る/開く
タイトル: Quantitative Susceptibility Mapping at 3 T and 1.5 T: Evaluation of Consistency and Reproducibility.
著者: Hinoda, Takuya  KAKEN_id  orcid https://orcid.org/0000-0001-8111-0153 (unconfirmed)
Fushimi, Yasutaka  kyouindb  KAKEN_id  orcid https://orcid.org/0000-0002-1982-3168 (unconfirmed)
Okada, Tomohisa  KAKEN_id  orcid https://orcid.org/0000-0003-2312-5677 (unconfirmed)
Fujimoto, Koji  kyouindb  KAKEN_id  orcid https://orcid.org/0000-0003-1209-7949 (unconfirmed)
Liu, Chunlei
Yamamoto, Akira  kyouindb  KAKEN_id  orcid https://orcid.org/0000-0002-8894-3622 (unconfirmed)
Okada, Tsutomu  KAKEN_id
Kido, Aki
Togashi, Kaori  KAKEN_id
著者名の別形: 日野田, 卓也
伏見, 育崇
キーワード: magnetic resonance imaging
発行日: 18-Apr-2015
出版者: Wolters Kluwer Health, Inc
誌名: Investigative radiology
巻: 50
号: 8
開始ページ: 522
終了ページ: 530
抄録: [Objectives]: The aim of this study was to assess the consistency and reproducibility of quantitative susceptibility mapping (QSM) at 3-T and 1.5-T magnetic resonance (MR) scanners. [Materials and Methods]: This study was approved by institutional ethics committee, and written informed consent was obtained. Twenty-two healthy volunteers underwent 2 examinations on different days. Each examination consisted of MR imaging on both 3-T and 1.5-T MR scanners. The data from both scanners and examination days were obtained, and QSM was calculated with STI Suite using 2 different algorithms-harmonic phase removal using laplacian operator (HARPERELLA) and a sophisticated harmonic artifact reduction for phase data (SHARP) method with a variable radius of the spherical kernel at the brain boundary (V-SHARP). We evaluated consistency of QSM between 3 T and 1.5 T and the reproducibility between the first and second examinations using 2-phase processing methods (HARPERELLA and V-SHARP). [Results]: Susceptibility values of regions of interests at 3 T were highly correlated with those at 1.5 T with good agreement (HARPERELLA, R2 = 0.838; V-SHARP, R2 = 0.898) (average difference, +/-1.96 SD; HARPERELLA, -0.012 +/- 0.046; V-SHARP, -0.002 +/- 0.034). Reproducibility analysis demonstrated excellent correlation between the first and second examination at both 3 T and 1.5 T for both algorithms (HARPERELLA at 3 T, R2 = 0.921; 1.5 T, R2 = 0.891; V-SHARP at 3 T, R2 = 0.937; 1.5 T, R2 = 0.926). Bland-Altman analysis showed excellent reproducibility for HARPERELLA (3 T, -0.003 +/- 0.032; 1.5 T, -0.003 +/- 0.038) and V-SHARP (3 T, -0.003 +/- 0.027; 1.5 T, -0.003 +/- 0.029). Susceptibility values of these 2 algorithms were highly correlated with good agreement (3T, R2 = 0.961; 1.5 T, R2 = 0.931) (3 T, 0.009 +/- 0.023; 1.5 T, -0.003 +/- 0.049). [Conclusions]: Quantitative susceptibility mapping with HARPERELLA and V-SHARP demonstrated good reproducibility at 3 T and 1.5 T, and QSM with V-SHARP demonstrated good consistency at 3 T and 1.5 T.
著作権等: © 2015 Wolters Kluwer Health. This is a non-final version of an article published in final form in Investigative Radiology: Post Author Corrections: April 18, 2015 doi: 10.1097/RLI.0000000000000159.
許諾条件により本文ファイルは2016-04-18に公開.
この論文は出版社版でありません。引用の際には出版社版をご確認ご利用ください。
This is not the published version. Please cite only the published version.
URI: http://hdl.handle.net/2433/197533
DOI(出版社版): 10.1097/RLI.0000000000000159
PubMed ID: 25900085
出現コレクション:学術雑誌掲載論文等

アイテムの詳細レコードを表示する

Export to RefWorks


出力フォーマット 


このリポジトリに保管されているアイテムはすべて著作権により保護されています。