ダウンロード数: 773
タイトル: | 経腰的連続大動脈撮影法 |
その他のタイトル: | Translumbar Serial Aortography |
著者: | 後藤, 薫 大森, 孝郎 仁平, 寛巳 酒徳, 治三郎 日野, 豪 片村, 永樹 |
著者名の別形: | GOTO, Kaoru OMORI, Takao NIHIRA, Hiromi SAKATOKU, Jisaburo HINO, Takeshi KATAMURA, Eizyu |
発行日: | Aug-1958 |
出版者: | 京都大学医学部泌尿器科教室 |
誌名: | 泌尿器科紀要 |
巻: | 4 |
号: | 8 |
開始ページ: | 421 |
終了ページ: | 435 |
抄録: | We have been taken translumbar serial aortograp h y in 37 cases and we report its into details. We reviewed about many sort of serial roentgenographic apparatus, but we used usually "rapid cassette changing devices-Shimadzu" as a most simply controlled, distinctly shadowing one. The pic t u re of the abdominal aorta, renal arteries, intrarenal arterioles and nephrogram was obtained time by time with serial taking, therefore this method follewed many significant diagnostic value, such as differentiation of renal tumor from cyst, accurate diagnosis of Goldblatt kidney, thromboarteritis obliterans and so on. Arteriogram, that is the figure of renal arteries and its intraren a l branches, was taken from 1 to 3 second (average 1.8 second), and nephrogram was 2-6 second (average 4.0 second) after initiation of translumbar injection of dye. We obtained aortogram and nephrogram satisfact o rily by 5 serial films with 1.0 second interval for clinical use. When the most fine arteriogram is required, 10 serial films with 0.5 second interval was available. |
URI: | http://hdl.handle.net/2433/111647 |
出現コレクション: | Vol.4 No.8 |
このリポジトリに保管されているアイテムはすべて著作権により保護されています。