このアイテムのアクセス数: 1041

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
22_0915.pdf1.59 MBAdobe PDF見る/開く
完全メタデータレコード
DCフィールド言語
dc.contributor.author川村, 寿一ja
dc.contributor.author細川, 進一ja
dc.contributor.author友吉, 唯夫ja
dc.contributor.author吉田, 修ja
dc.contributor.alternativeKawamura, Juichien
dc.contributor.alternativeHosokawa, Shinichien
dc.contributor.alternativeTomoyoshi, Tadaoen
dc.contributor.alternativeYoshida, Osamuen
dc.date.accessioned2010-07-06T11:14:09Z-
dc.date.available2010-07-06T11:14:09Z-
dc.date.issued1976-12-
dc.identifier.issn0018-1994-
dc.identifier.urihttp://hdl.handle.net/2433/122023-
dc.description.abstractA survey was carried out to determine the sort and frequency of microorganisms isolated from infected urines in the outpatient clinic for two years (1975, 1976). Microstix-3 test paper to screen a significant bacteriuria was also evaluated. E. coli was a most frequently isolated organism in 30-40% out of urinary pathogens and there was no big change in frequencies of other gram negative rods comparing with a survey in 1974. However, a tendency was found that gram positive cocci gradually increased in frequency. 70% of complete accuracy and 75% of allowable reliability were obtained from a comparison made between total bacterial count in Microstix-3 and colony count obtained from the standard bacterial culture in the central laboratory. This paper could also detect 84.3% of significant bacteriuria in the presence of infected urines with colony count more than 10[5]/ml. The part reacted to gram negative rods was useful for differentiating gram negative rods from gram positive cocci. When the part of nitrite color indicator turned a variable shade of red, it was convinced that a significant bacteriuria of gram negative rods more than 10[5]/ml existed in the specimen. In conclusion, Microstix-3 paper may be applicable to evaluate a bacteriuria in the outpatient clinic.en
dc.format.mimetypeapplication/pdf-
dc.language.isojpn-
dc.publisher京都大学医学部泌尿器科学教室ja
dc.publisher.alternativeDepartment of Urology, Faculty of Medicine, Kyoto Univeersityen
dc.subject.ndc494.9-
dc.title外来診療における細菌尿のスクリーニング -尿半定量培養のためのMicrostix-3の評価-ja
dc.title.alternativeEVALUATION OF MICROSTIX-3 TO DETECT A SIGNIFICANT BACTERIURIA IN THE OUTPATIENT CLINICen
dc.typedepartmental bulletin paper-
dc.type.niitypeDepartmental Bulletin Paper-
dc.identifier.ncidAN00208315-
dc.identifier.jtitle泌尿器科紀要ja
dc.identifier.volume22-
dc.identifier.issue8-
dc.identifier.spage915-
dc.identifier.epage920-
dc.textversionpublisher-
dc.sortkey15-
dc.address京都大学医学部泌尿器科学教室ja
dc.address.alternativeTheDepartment of Urology, Faculty of Medicine, Kyoto Universityen
dcterms.accessRightsopen access-
dc.identifier.pissn0018-1994-
dc.identifier.jtitle-alternativeActa urologica Japonicala
dc.identifier.jtitle-alternativeHinyokika Kiyoen
出現コレクション:Vol.22 No.8

アイテムの簡略レコードを表示する

Export to RefWorks


出力フォーマット 


このリポジトリに保管されているアイテムはすべて著作権により保護されています。