このアイテムのアクセス数: 545
このアイテムのファイル:
ファイル | 記述 | サイズ | フォーマット | |
---|---|---|---|---|
TITB.2012.2210434.pdf | 11.91 MB | Adobe PDF | 見る/開く |
タイトル: | Embedded Ubiquitous Services on Hospital Information Systems. |
著者: | Kuroda, Tomohiro ![]() ![]() ![]() Sasaki, Hiroshi Suenaga, Takatoshi Masuda, Yasushi Yasumuro, Yoshihiro Hori, Yasushi Ohboshi, Naoki Takemura, Tadamasa Chihara, Kunihiro Yoshihara, Hiroyuki |
著者名の別形: | 黒田, 知宏 佐々木, 博史 末永, 貴俊 増田, 泰 安室, 喜弘 堀, 謙太 大星, 直樹 竹村, 匡正 千原, 國宏 吉原, 博幸 |
キーワード: | Digital Camera echograph hospital hnformation system (HIS) ubiquitous computing |
発行日: | Nov-2012 |
出版者: | IEEE |
誌名: | IEEE transactions on information technology in biomedicine : a publication of the IEEE Engineering in Medicine and Biology Society |
巻: | 16 |
号: | 6 |
開始ページ: | 1216 |
終了ページ: | 1223 |
抄録: | A Hospital Information Systems (HIS) have turned a hospital into a gigantic computer with huge computational power, huge storage and wired/wireless local area network. On the other hand, a modern medical device, such as echograph, is a computer system with several functional units connected by an internal network named a bus. Therefore, we can embed such a medical device into the HIS by simply replacing the bus with the local area network. This paper designed and developed two embedded systems, a ubiquitous echograph system and a networked digital camera. Evaluations of the developed systems clearly show that the proposed approach, embedding existing clinical systems into HIS, drastically changes productivity in the clinical field. Once a clinical system becomes a pluggable unit for a gigantic computer system, HIS, the combination of multiple embedded systems with application software designed under deep consideration about clinical processes may lead to the emergence of disruptive innovation in the clinical field. |
著作権等: | © 2012 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. This is not the published version. Please cite only the published version. この論文は出版社版でありません。引用の際には出版社版をご確認ご利用ください。 |
URI: | http://hdl.handle.net/2433/168184 |
DOI(出版社版): | 10.1109/TITB.2012.2210434 |
PubMed ID: | 22855229 |
出現コレクション: | 学術雑誌掲載論文等 |

このリポジトリに保管されているアイテムはすべて著作権により保護されています。