ダウンロード数: 410

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
j.aca.2012.12.052.pdf950.45 kBAdobe PDF見る/開く
完全メタデータレコード
DCフィールド言語
dc.contributor.authorNieh, Chi-Huaen
dc.contributor.authorTsujimura, Seiyaen
dc.contributor.authorShirai, Osamuen
dc.contributor.authorKano, Kenjien
dc.contributor.alternative加納, 健司ja
dc.date.accessioned2013-04-04T00:49:57Z-
dc.date.available2013-04-04T00:49:57Z-
dc.date.issued2013-03-12-
dc.identifier.issn0003-2670-
dc.identifier.urihttp://hdl.handle.net/2433/173085-
dc.description.abstractPentacyanoferrate-bound poly(1-vinylimidazole) (PVI[Fe(CN)5]) was selected as a mediator for amperometric creatinine determination based on the reductive H2O2 detection. Creatinine amidohydrolase (CNH), creatine amidohydrolase (CRH), sarcosine oxidase (SOD), peroxidase (POD), and PVI[Fe(CN)5] were crosslinked with poly(ethylene glycol) diglycidyl ether (PEGDGE) on a glassy carbon (GC) electrode for a creatinine biosensor fabrication. Reduction current was monitored at −0.1 V in the presence of creatinine and O2. It is revealed that PVI[Fe(CN)5] is suitable as a mediator for a bioelectrocatalytic reaction of POD, since PVI[Fe(CN)5] neither reacts with reactants nor works as an electron acceptor of SOD. The amounts of PVI[Fe(CN)5], PEGDGE, and enzymes were optimized toward creatinine detection. Nafion as a protecting film successfully prevented the enzyme layer from interferences. The detection limit and linear range in creatinine determination were 12 μM and 12–500 μM (R[2]= 0.993), respectively, and the sensitivity was 11 mA cm[−2] M[−1], which is applicable for urine creatinine tests. The results of the creatinine determination for four urine samples measured with this proposed method were compared with Jaffe method, and a good correlation was obtained between the results.en
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherElsevier B.V.en
dc.rights© 2013 Elsevier B.V.en
dc.rightsこの論文は出版社版でありません。引用の際には出版社版をご確認ご利用ください。ja
dc.rightsThis is not the published version. Please cite only the published version.en
dc.subjectPentacyanoferrate-bound poly(1-vinylimidazole)en
dc.subjectCreatinine amidohydrolaseen
dc.subjectReductive H2O2 detectionen
dc.subjectPeroxidaseen
dc.subjectNafionen
dc.subjectUrine creatinine testen
dc.titleAmperometric biosensor based on reductive H2O2 detection using pentacyanoferrate-bound polymer for creatinine determination.en
dc.typejournal article-
dc.type.niitypeJournal Article-
dc.identifier.ncidAA00524834-
dc.identifier.jtitleAnalytica chimica actaen
dc.identifier.volume767-
dc.identifier.spage128-
dc.identifier.epage133-
dc.relation.doi10.1016/j.aca.2012.12.052-
dc.textversionauthor-
dc.identifier.pmid23452796-
dcterms.accessRightsopen access-
出現コレクション:学術雑誌掲載論文等

アイテムの簡略レコードを表示する

Export to RefWorks


出力フォーマット 


このリポジトリに保管されているアイテムはすべて著作権により保護されています。