このアイテムのアクセス数: 273

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
jrr_rrs076.pdf536.6 kBAdobe PDF見る/開く
完全メタデータレコード
DCフィールド言語
dc.contributor.authorMizowaki, Takashien
dc.contributor.authorTakayama, Kenjien
dc.contributor.authorNagano, Kazuoen
dc.contributor.authorMiyabe, Yukien
dc.contributor.authorMatsuo, Yukinorien
dc.contributor.authorKaneko, Shujien
dc.contributor.authorKokubo, Masakien
dc.contributor.authorHiraoka, Masahiroen
dc.contributor.alternative溝脇, 尚志ja
dc.date.accessioned2013-04-15T00:27:04Z-
dc.date.available2013-04-15T00:27:04Z-
dc.date.issued2013-03-01-
dc.identifier.issn0449-3060-
dc.identifier.urihttp://hdl.handle.net/2433/173186-
dc.description.abstractThe Vero4DRT (MHI-TM2000) is a newly designed unique image-guided radiotherapy system consisting of an O-ring gantry. This system can realize a new irradiation technique in which both the gantry head and O-ring continuously and simultaneously rotate around the inner circumference of the O-ring and the vertical axis of the O-ring, respectively, during irradiation. This technique creates three-dimensional (3D) rotational dynamic conformal arc irradiation, which we term '3D unicursal irradiation'. The aim of this study was to present the concept and to estimate feasibility and potential advantages of the new irradiation technique. Collision maps were developed for the technique and a 3D unicursal plan was experimentally created in reference to the collision map for a pancreatic cancer case. Thereafter, dosimetric comparisons among the 3D unicursal, a two-dimensionally rotational dynamic conformal arc irradiation (2D-DCART), and an intensity-modulated radiation therapy (IMRT) plan were conducted. Dose volume data of the 3D unicursal plan were comparable or improved compared to those of the 2D-DCART and IMRT plans with respect to both the target and the organs at risk. The expected monitor unit (MU) number for the 3D unicursal plan was only 7% higher and 22.1% lower than the MUs for the 2D-DCART plan and IMRT plan, respectively. It is expected that the 3D unicursal irradiation technique has potential advantages in both treatment time and dose distribution, which should be validated under various conditions with a future version of the Vero4DRT fully implemented the function.en
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherOxford University Pressen
dc.rights© The Author 2012. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Therapeutic Radiology and Oncology.en
dc.rightsThis is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly citeden
dc.subjectthree-dimensional unicursal irradiationen
dc.subjectdynamic conformal arc irradiationen
dc.subjectimage-guided radiotherapyen
dc.subjectnew irradiation techniqueen
dc.subjectdynamic wave arc irradiationen
dc.titleFeasibility evaluation of a new irradiation technique: three-dimensional unicursal irradiation with the Vero4DRT (MHI-TM2000).en
dc.typejournal article-
dc.type.niitypeJournal Article-
dc.identifier.ncidAA00705792-
dc.identifier.jtitleJournal of radiation researchen
dc.identifier.volume54-
dc.identifier.issue2-
dc.identifier.spage330-
dc.identifier.epage336-
dc.relation.doi10.1093/jrr/rrs076-
dc.textversionpublisher-
dc.identifier.pmid22923744-
dcterms.accessRightsopen access-
出現コレクション:学術雑誌掲載論文等

アイテムの簡略レコードを表示する

Export to RefWorks


出力フォーマット 


このリポジトリに保管されているアイテムはすべて著作権により保護されています。