このアイテムのアクセス数: 472

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
j.nima.2014.02.007.pdf1.3 MBAdobe PDF見る/開く
タイトル: A vacuum tolerant high voltage system with a low noise and low power Cockcroft–Walton photomultiplier base
著者: Masuda, T.
Iwai, E.
Kawasaki, N.
Kim, E.J.
Komatsubara, T.K.
Lee, J.W.
Lim, G.Y.
Maeda, Y.
Naito, D.
Nanjo, H.
Nomura, T.
Ri, Y.D.
Sasao, N.
Sato, K.
Seki, S.
Shiomi, K.
Sugiyama, Y.
Togawa, M.
Watanabe, H.
Yamanaka, T.
著者名の別形: 増田, 孝彦
キーワード: J-PARC
KOTO
Calorimeter
CW base
Photomultiplier tube
発行日: 11-May-2014
出版者: Elsevier B.V.
誌名: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
巻: 746
開始ページ: 11
終了ページ: 19
抄録: We developed a high voltage system for the electromagnetic calorimeter of the KOTO detector. The system is designed around a low noise, low power Cockcroft–Walton (CW) photomultiplier tube base with a high gain preamplifier. The low power makes it suitable for operations in vacuum. The low noise and high gain allow detecting signals in the 1 MeV range. We achieved a final noise level below 180 μV[rms] for a preamplifier gain of more than 40. A vacuum tolerant control system for the CW bases power distribution was also designed. This system is able to control and monitor the high voltage of each individual base.
著作権等: © 2014 Elsevier B.V.
This is not the published version. Please cite only the published version.
この論文は出版社版でありません。引用の際には出版社版をご確認ご利用ください。