dc.contributor.author | Fukuda, Jun | en |
dc.contributor.author | Iura, Takafumi | en |
dc.contributor.author | Yanagihara, Shigehiro | en |
dc.contributor.author | Kano, Kenji | en |
dc.contributor.alternative | 加納, 健司 | ja |
dc.date.accessioned | 2014-04-17T05:21:37Z | - |
dc.date.available | 2014-04-17T05:21:37Z | - |
dc.date.issued | 2014-03-15 | - |
dc.identifier.issn | 1570-0232 | - |
dc.identifier.uri | http://hdl.handle.net/2433/185681 | - |
dc.description.abstract | Size-exclusion chromatography (SEC) is a useful method for quantification of protein aggregates because of its high throughput capacity and highly quantitative performance. One of the problems in this method concerns polysorbates, which are well-known additives for protein-containing products to prevent protein aggregation, but frequently interfere with the photometric detection of protein aggregates. We developed a new SEC method that can separate polysorbates from protein sample solutions in an on-line mode with a precolumn with size exclusion and reversed-phase mixed modes. The precolumn can effectively trap polysorbates in aqueous mobile phase, and the trapped polysorbates are easily eluted with acetonitrile-containing aqueous mobile phase to clean the precolumn. Small parts of protein aggregates may be also trapped on the precolumn depending on temperature and proteins. Setting appropriate column temperature can minimize such inconvenient trapping of aggregates. | en |
dc.format.mimetype | application/pdf | - |
dc.language.iso | eng | - |
dc.publisher | Elsevier B.V. | en |
dc.rights | © 2014 Elsevier B.V. | en |
dc.rights | この論文は出版社版でありません。引用の際には出版社版をご確認ご利用ください。 | ja |
dc.rights | This is not the published version. Please cite only the published version. | en |
dc.subject | Size-exclusion chromatography | en |
dc.subject | Polysorbate | en |
dc.subject | Protein aggregation | en |
dc.subject | MSpak GF-4A | en |
dc.subject | Temperature-dependent retention | en |
dc.title | Utilization of a precolumn with size exclusion and reversed-phase modes for size-exclusion chromatographic analysis of polysorbate-containing protein aggregates. | en |
dc.type | journal article | - |
dc.type.niitype | Journal Article | - |
dc.identifier.ncid | AA11656178 | - |
dc.identifier.jtitle | Journal of chromatography. B, Analytical technologies in the biomedical and life sciences | en |
dc.identifier.volume | 953-954 | - |
dc.identifier.spage | 68 | - |
dc.identifier.epage | 72 | - |
dc.relation.doi | 10.1016/j.jchromb.2014.01.052 | - |
dc.textversion | author | - |
dc.identifier.pmid | 24576768 | - |
dcterms.accessRights | open access | - |
出現コレクション: | 学術雑誌掲載論文等 |