Title: 透析用ePTFEグラフトに生じた血清腫の1例
Other Titles: Seroma Formation Associated with Expanded Polytetrafluoroethylene Graft Used for Dialysis Access : A Case Report
Authors: 佐々木, 雄太郎  KAKEN_name
塩崎, 啓登  KAKEN_name
尾崎, 啓介  KAKEN_name
飯尾, 浩之  KAKEN_name
小田, 眞平  KAKEN_name
藤方, 史朗  KAKEN_name
菅, 政治  KAKEN_name
Author's alias: Sasaki, Yutaro
Shiozaki, Keito
Ozaki, Keisuke
Iio, Hiroyuki
Oda, Shimpei
Fujikata, Shiro
Kan, Masaharu
Keywords: Seroma
ePTFE graft
Issue Date: Oct-2014
Publisher: 泌尿器科紀要刊行会
Journal title: 泌尿器科紀要 = Acta urologica Japonica
Volume: 60
Issue: 10
Start page: 489
End page: 491
Abstract: The patient was a 67-year-old man with end stage renal failure. Hemodialysis had been started in 1998. An expanded polytetrafluoroethylene (PTFE) graft was inserted into his left forearm and used for vascular access. He received a partial replacement of the expanded PTFE graft in September 2013. A seroma formed after this intervention and subsequently grew larger. He thus underwent seroma removal and bypass graft surgery. Four months after the surgery, to date, he remains free of seroma recurrence.