ダウンロード数: 389
このアイテムのファイル:
ファイル | 記述 | サイズ | フォーマット | |
---|---|---|---|---|
j.ab.2014.08.029.pdf | 508.72 kB | Adobe PDF | 見る/開く |
完全メタデータレコード
DCフィールド | 値 | 言語 |
---|---|---|
dc.contributor.author | Toda, Mitsuaki | en |
dc.contributor.author | Arima, Yusuke | en |
dc.contributor.author | Takiguchi, Hiromi | en |
dc.contributor.author | Iwata, Hiroo | en |
dc.contributor.alternative | 有馬, 祐介 | ja |
dc.contributor.alternative | 岩田, 博夫 | ja |
dc.date.accessioned | 2014-11-28T03:06:53Z | - |
dc.date.available | 2014-11-28T03:06:53Z | - |
dc.date.issued | 2014-09-06 | - |
dc.identifier.issn | 0003-2697 | - |
dc.identifier.uri | http://hdl.handle.net/2433/191329 | - |
dc.description.abstract | Surface plasmon field-enhanced fluorescence spectroscopy (SPFS) is a promising methodology for point-of-care (POC) testing. The SPFS devices that have been reported are equipped with an angle rotating stage to adjust the surface plasmon resonance (SPR) angle. In a clinical setting, however, the SPR angle determination is a tedious and time-consuming process. In this study, we employed an SPFS instrument with a convergent optical system that allows the omission of this procedure. We demonstrated that this instrumentation allowed the sensitive determination of low concentrations of α-fetoprotein in serum and reduced the variation effect caused by the protein concentrations in samples. The SPFS with a convergent optical system is suitable for POC testing. | en |
dc.format.mimetype | application/pdf | - |
dc.language.iso | eng | - |
dc.publisher | Elsevier Inc. | en |
dc.rights | © 2014 Elsevier Inc. | en |
dc.rights | この論文は出版社版でありません。引用の際には出版社版をご確認ご利用ください。 | ja |
dc.rights | This is not the published version. Please cite only the published version. | en |
dc.subject | Surface plasmon field-enhanced fluorescence spectroscopy | en |
dc.subject | Convergent optical system | en |
dc.subject | Tumor marker | en |
dc.subject | Highly sensitive detection | en |
dc.title | Surface plasmon field-enhanced fluorescence spectroscopy apparatus with a convergent optical system for point-of-care testing. | en |
dc.type | journal article | - |
dc.type.niitype | Journal Article | - |
dc.identifier.jtitle | Analytical biochemistry | en |
dc.identifier.volume | 467 | - |
dc.identifier.issue | 15 | - |
dc.identifier.spage | 47 | - |
dc.identifier.epage | 53 | - |
dc.relation.doi | 10.1016/j.ab.2014.08.029 | - |
dc.textversion | author | - |
dc.identifier.pmid | 25197029 | - |
dcterms.accessRights | open access | - |
出現コレクション: | 学術雑誌掲載論文等 |
このリポジトリに保管されているアイテムはすべて著作権により保護されています。