dc.description.abstractWe present two cases of aortic valve replacement (AVR) in patients with protruding coronary artery stents from the coronary ostia. In the first case, an 87-year-old female was referred for AVR due to severe aortic stenosis (AS). During the operation, we found stents protruding from the left and the right coronary ostia into the aortic root. We performed AVR with a mechanical valve and coronary artery bypass grafting with the saphenous vein to the left anterior descending artery. In the second case, a 77-year-old female was referred for AVR due to severe AS with a history of healed infective endocarditis. During surgery on the second patient, we found a stent protruding 7 mm from the left coronary ostium into the aortic root. The edge of the stent was trimmed, and AVR with a mechanical valve was performed. In both patients, we decided to use a mechanical prosthesis instead of a bioprosthesis because of the risk of leaflet injury. Herein, we discuss some issues regarding patients with AS requiring AVR with prior history of coronary stenting in the coronary ostia.en
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherElsevier BVen
dc.rights© 2014 Japanese College of Cardiology. Published by Elsevier Ltd.en
dc.rightsこの論文は出版社版でありません。引用の際には出版社版をご確認ご利用ください。ja
dc.rightsThis is not the published version. Please cite only the published version.en
dc.subjectAortic valve replacementen
dc.subjectPercutaneous coronary interventionen
dc.subjectStent protrusionen
dc.subjectValve prosthesisen
dc.titleAortic valve replacement in patients with protruding coronary artery stentsen
dc.typejournal article-
dc.type.niitypeJournal Article-
dc.identifier.jtitleJournal of Cardiology Casesen
dc.identifier.volume10-
dc.identifier.issue6-
dc.identifier.spage213-
dc.identifier.epage215-
dc.relation.doi10.1016/j.jccase.2014.07.013-
dc.textversionauthor-
dc.identifier.pmid30534246-
dcterms.accessRightsopen access-
dc.identifier.pissn1878-5409-
出現コレクション:学術雑誌掲載論文等

アイテムの簡略レコードを表示する

Export to RefWorks


出力フォーマット 


このリポジトリに保管されているアイテムはすべて著作権により保護されています。