タイトル: Revising the existing Performance Indicator system for small water supply utilities in Japan
著者: Shinde, Victor Rana
Hirayama, Nagahisa
Mugita, Ai
Itoh, Sadahiko  kyouindb  KAKEN_id  orcid https://orcid.org/0000-0002-4328-7879 (unconfirmed)
著者名の別形: 伊藤, 禎彦
キーワード: benchmarking
PDCA cycle
Performance Indicators
Principal Component Analysis
small water utilities
発行日: Dec-2013
出版者: Taylor & Francis Group
誌名: Urban Water Journal
巻: 10
号: 6
開始ページ: 377
終了ページ: 393
抄録: 97.5% of the water utilities in Japan serve less than 50, 000 customers, and are called small water utilities. The Performance Indicator system in Japan, used to evaluate the performance of various aspects of the supply system, currently has 137 items, which are too many in number for the small utilities to adopt because of resource and financial constraints. The objective of this study is to, thus, revise the existing PI system to arrive at a reduced, relevant and practical structure that provides enough information to rationally evaluate small water supply systems in Japan. Principal Component Analysis was used to reduce the dimensionality of the original data. The results suggest that only nine components, consisting of 33 items (called 9-cPIS), are sufficient for evaluating the small water utilities. The effectiveness of the 9-cPIS in benchmarking, evaluating business models, and the planning and management of the water utilities has been discussed further.
著作権等: The Version of Record of this manuscript has been published and is available in Urban Water Journal (2013) http://www.tandfonline.com/10.1080/1573062X.2012.739628.
この論文は出版社版でありません。引用の際には出版社版をご確認ご利用ください。
This is not the published version. Please cite only the published version.