このアイテムのアクセス数: 193

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
transinf.e96.d.1387.pdf534.38 kBAdobe PDF見る/開く
完全メタデータレコード
DCフィールド言語
dc.contributor.authorNagahara, Shizueen
dc.contributor.authorOida, Takenorien
dc.contributor.authorKobayashi, Tetsuoen
dc.date.accessioned2015-02-18T06:34:43Z-
dc.date.available2015-02-18T06:34:43Z-
dc.date.issued2013-06-01-
dc.identifier.issn0916-8532-
dc.identifier.urihttp://hdl.handle.net/2433/194148-
dc.description.abstractDiffusion-weighted (DW)-functional magnetic resonance imaging (fMRI) is a recently reported technique for measuring neural activities by using diffusion-weighted imaging (DWI). DW-fMRI is based on the property that cortical cells swell when the brain is activated. This approach can be used to observe changes in water diffusion around cortical cells. The spatial and temporal resolutions of DW-fMRI are superior to those of blood-oxygenation-level-dependent (BOLD)-fMRI. To investigate how the DWI signal intensities change in DW-fMRI measurement, we carried out Monte Carlo simulations to evaluate the intensities before and after cell swelling. In the simulations, we modeled cortical cells as two compartments by considering differences between the intracellular and the extracellular regions. Simulation results suggested that DWI signal intensities increase after cell swelling because of an increase in the intracellular volume ratio. The simulation model with two compartments, which respectively represent the intracellular and the extracellular regions, shows that the differences in the DWI signal intensities depend on the ratio of the intracellular and the extracellular volumes. We also investigated the MPG parameters, b-value, and separation time dependences on the percent signal changes in DW-fMRI and obtained useful results for DW-fMRI measurements.en
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherInstitute of Electronics, Information and Communication Engineers(IEICE)en
dc.publisher.alternative一般社団法人 電子情報通信学会ja
dc.rightscopyright ©2013 by IEICEen
dc.subjectfunctional magnetic resonance imagingen
dc.subjectdiffusion-weighted imagingen
dc.subjectrestricted diffusionen
dc.subjectMonte Carlo methoden
dc.titleAn Explanation of Signal Changes in DW-fMRI: Monte Carlo Simulation Study of Restricted Diffusion of Water Molecules Using 3D and Two-Compartment Cortical Cell Modelsen
dc.typejournal article-
dc.type.niitypeJournal Article-
dc.identifier.ncidAA10826272-
dc.identifier.jtitleIEICE Transactions on Information and Systemsen
dc.identifier.volumeE96-D-
dc.identifier.issue6-
dc.identifier.spage1387-
dc.identifier.epage1393-
dc.relation.doi10.1587/transinf.e96.d.1387-
dc.textversionpublisher-
dcterms.accessRightsopen access-
出現コレクション:学術雑誌掲載論文等

アイテムの簡略レコードを表示する

Export to RefWorks


出力フォーマット 


このリポジトリに保管されているアイテムはすべて著作権により保護されています。