dc.description.abstractBecause fine particulate matter ≤2.5 µm in diameter (PM2.5) causes health problems, PM2.5 emissions are of concern. However, little research on stationary sources has been conducted. To determine the concentration and filtration behavior of PM2.5, dust was collected from five fluid-bed sewage sludge incinerators (SSIs) sorted by particle size using cascade impactors. The average PM2.5 concentration was 0.00014–4.8 mg/Nm3. The total estimated amount of PM2.5 emissions from the SSIs for all plants in Japan was 0.96–8.9 tons/year. Since the SSIs with dry Electrostatic Precipitators (EP) contributed 75–99% of the total emissions, replacing dry EPs with bag filters would significantly reduce the PM2.5 emissions from SSI.en
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherTaylor & Francis Groupen
dc.rightsThis is an Accepted Manuscript of an article published by Taylor & Francis in 'Drying Technology: An International Journal (2015)', available online: http://www.tandfonline.com/10.1080/07373937.2015.1026977.en
dc.rightsThe full-text file will be made open to the public on 15 April 2016 in accordance with publisher's 'Terms and Conditions for Self-Archiving'.en
dc.rightsThis is not the published version. Please cite only the published version.en
dc.rightsこの論文は出版社版でありません。引用の際には出版社版をご確認ご利用ください。ja
dc.subjectBag filteren
dc.subjectElectrostatic precipitatoren
dc.subjectEmissionen
dc.subjectPM2.5en
dc.subjectSewage sludge incineratoren
dc.titleEmission of Particulate Matter 2.5 (PM2.5) from Sewage Sludge Incinerators in Japanen
dc.typejournal article-
dc.type.niitypeJournal Article-
dc.identifier.ncidAA10636517-
dc.identifier.jtitleDrying Technologyen
dc.identifier.volume33-
dc.identifier.issue11-
dc.identifier.spage1286-
dc.identifier.epage1294-
dc.relation.doi10.1080/07373937.2015.1026977-
dc.textversionauthor-
dc.startdate.bitstreamsavailable2016-04-15-
dcterms.accessRightsopen access-
出現コレクション:学術雑誌掲載論文等

アイテムの簡略レコードを表示する

Export to RefWorks


出力フォーマット 


このリポジトリに保管されているアイテムはすべて著作権により保護されています。