Downloads: 639

Files in This Item:
File Description SizeFormat 
jkps.67.76.pdf473.33 kBAdobe PDFView/Open
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSakurai, Yoshinorija
dc.contributor.authorTanaka, Hirokija
dc.contributor.authorTakata, Takushija
dc.contributor.authorFujimoto, Nozomija
dc.contributor.authorSuzuki, Minoruja
dc.contributor.authorMasunaga, Shinichiroja
dc.contributor.authorKinashi, Yukoja
dc.contributor.authorKondo, Natsukoja
dc.contributor.authorNarabayashi, Masaruja
dc.contributor.authorNakagawa, Yosukeja
dc.contributor.authorWatanabe, Tsubasaja
dc.contributor.authorOno, Kojija
dc.contributor.authorMaruhashi, Akiraja
dc.contributor.alternative櫻井, 良憲ja
dc.date.accessioned2015-12-01T00:32:18Z-
dc.date.available2015-12-01T00:32:18Z-
dc.date.issued2015-07ja
dc.identifier.issn0374-4884ja
dc.identifier.urihttp://hdl.handle.net/2433/202015-
dc.descriptionFirst online: 28 July 2015ja
dc.description.abstractAt the Kyoto University Research Reactor Institute (KURRI), a clinical study of boron neutron capture therapy (BNCT) using a neutron irradiation facility installed at the research nuclear reactor has been regularly performed since February 1990. As of November 2014, 510 clinical irradiations were carried out using the reactor-based system. The world’s first accelerator-based neutron irradiation system for BNCT clinical irradiation was completed at this institute in early 2009, and the clinical trial using this system was started in 2012. A shift of BCNT from special particle therapy to a general one is now in progress. To promote and support this shift, improvements to the irradiation system, as well as its preparation, and improvements in the physical engineering and the medical physics processes, such as dosimetry systems and quality assurance programs, must be considered. The recent advances in BNCT at KURRI are reported here with a focus on physical engineering and medical physics topics.ja
dc.format.mimetypeapplication/pdfja
dc.language.isoengja
dc.publisherThe Korean Physical Societyja
dc.rightsThe final publication is available at Springer via http://dx.doi.org/10.3938/jkps.67.76.ja
dc.rightsThe full-text file will be made open to the public on 28 July 2016 in accordance with publisher's 'Terms and Conditions for Self-Archiving'.ja
dc.rightsThis is not the published version. Please cite only the published version. この論文は出版社版でありません。引用の際には出版社版をご確認ご利用ください。ja
dc.subjectBoron neutron capture therapyja
dc.subjectBNCTja
dc.subjectReactor-based systemja
dc.subjectAccelerator-based systemja
dc.titleAdvances in boron neutron capture therapy (BNCT) at kyoto university - From reactor-based BNCT to accelerator-based BNCTja
dc.type.niitypeJournal Articleja
dc.identifier.jtitleJournal of the Korean Physical Societyja
dc.identifier.volume67ja
dc.identifier.issue1ja
dc.identifier.spage76ja
dc.identifier.epage81ja
dc.relation.doi10.3938/jkps.67.76ja
dc.textversionauthorja
dc.startdate.bitstreamsavailable2016-07-28ja
Appears in Collections:Journal Articles