ダウンロード数: 163
このアイテムのファイル:
ファイル | 記述 | サイズ | フォーマット | |
---|---|---|---|---|
j.jccase.2015.05.006.pdf | 608.5 kB | Adobe PDF | 見る/開く |
完全メタデータレコード
DCフィールド | 値 | 言語 |
---|---|---|
dc.contributor.author | Yanagisawa, Hiromu | en |
dc.contributor.author | Saito, Naritatsu | en |
dc.contributor.author | Imai, Masao | en |
dc.contributor.author | Minakata, Kenji | en |
dc.contributor.author | Fujita, Takanari | en |
dc.contributor.author | Watanabe, Shin | en |
dc.contributor.author | Watanabe, Hirotoshi | en |
dc.contributor.author | Yamazaki, Kazuhiro | en |
dc.contributor.author | Toyota, Toshiaki | en |
dc.contributor.author | Taniguchi, Tomohiko | en |
dc.contributor.author | Tazaki, Junichi | en |
dc.contributor.author | Shizuta, Satoshi | en |
dc.contributor.author | Daijo, Hiroki | en |
dc.contributor.author | Sakata, Ryuzo | en |
dc.contributor.author | Kimura, Takeshi | en |
dc.contributor.alternative | 齋藤, 成達 | ja |
dc.date.accessioned | 2016-01-12T05:16:55Z | - |
dc.date.available | 2016-01-12T05:16:55Z | - |
dc.date.issued | 2015-10 | - |
dc.identifier.issn | 1878-5409 | - |
dc.identifier.uri | http://hdl.handle.net/2433/203022 | - |
dc.description.abstract | In Japan, transcatheter aortic valve implantation (TAVI) with Edwards-SAPIEN XT valve (Edwards Lifesciences Inc., Irvine, CA, USA) started in October 2013. All institutions should undergo a training period to perform TAVI independently. Balloon aortic valvuloplasty (BAV) as a bridge to TAVI during the training period should be performed with caution to avoid severe aortic regurgitation (AR) because bailout TAVI is not possible. We present a case in which BAV was successfully performed as a bridge to TAVI during the training period. The patient was an 85-year-old man with medically uncontrollable congestive heart failure due to severe aortic valve stenosis. The aortic valve area was 0.60 cm2 with a left ventricular ejection fraction of 20%. TAVI was considered a safe but high-risk strategy owing to the unstable hemodynamic condition. We chose BAV as a bridge therapy to TAVI. The aortic annulus diameter was 25.3 mm on computed tomography scans. We chose a 20-mm balloon catheter to avoid BAV-induced AR. Transfemoral TAVI was performed successfully 16 days after BAV using a 26-mm SAPIEN XT valve. The postoperative course was uneventful. The case demonstrated BAV as a bridge therapy to TAVI can be safely and effectively performed during the training period. | en |
dc.format.mimetype | application/pdf | - |
dc.language.iso | eng | - |
dc.publisher | Elsevier BV | en |
dc.rights | © 2015. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/ | en |
dc.rights | The full-text file will be made open to the public on 1 October 2016 in accordance with publisher's 'Terms and Conditions for Self-Archiving'. | en |
dc.rights | この論文は出版社版でありません。引用の際には出版社版をご確認ご利用ください。 | ja |
dc.rights | This is not the published version. Please cite only the published version. | en |
dc.subject | Balloon aortic valvuloplasty | en |
dc.subject | Transcatheter aortic valve implantation | en |
dc.subject | Transcatheter aortic valve replacement | en |
dc.title | Successful balloon aortic valvuloplasty as a bridge therapy to transcatheter aortic valve implantation during the proctoring period | en |
dc.type | journal article | - |
dc.type.niitype | Journal Article | - |
dc.identifier.jtitle | Journal of Cardiology Cases | en |
dc.identifier.volume | 12 | - |
dc.identifier.issue | 4 | - |
dc.identifier.spage | 113 | - |
dc.identifier.epage | 116 | - |
dc.relation.doi | 10.1016/j.jccase.2015.05.006 | - |
dc.textversion | author | - |
dc.startdate.bitstreamsavailable | 2016-10-01 | - |
dc.identifier.pmid | 30546571 | - |
dcterms.accessRights | open access | - |
dc.identifier.pissn | 1878-5409 | - |
出現コレクション: | 学術雑誌掲載論文等 |
このリポジトリに保管されているアイテムはすべて著作権により保護されています。