ダウンロード数: 174

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
s13018-015-0197-5.pdf801.6 kBAdobe PDF見る/開く
完全メタデータレコード
DCフィールド言語
dc.contributor.authorKawahara, Shinyaen
dc.contributor.authorOkazaki, Kenen
dc.contributor.authorMatsuda, Shuichien
dc.contributor.authorNakahara, Hiroyukien
dc.contributor.authorOkamoto, Shigetoshien
dc.contributor.authorIwamoto, Yukihideen
dc.contributor.alternative松田, 秀一ja
dc.date.accessioned2016-06-06T06:13:53Z-
dc.date.available2016-06-06T06:13:53Z-
dc.date.issued2015-04-25-
dc.identifier.issn1749-799X-
dc.identifier.urihttp://hdl.handle.net/2433/214468-
dc.description.abstract[Background]The configuration of the distal surface of the femur would be more important in terms of the patellofemoral (PF) joint contact because the patella generally contacts with the distal surface of the femur in knee flexion. Some total knee arthroplasty (TKA) designs configurate medially prominent asymmetric femoral condyles. This difference in the design of distal femoral condyle may affect the PF joint congruity in knee flexion. Furthermore, some surgeons advocate a concept aligning the symmetric components parallel to the native joint inclination, not perpendicular to the mechanical axis. This concept would also make a difference on the PF joint congruity at the distal femur in knee flexion. However, no fundamental study has been reported on the PF congruity at the distal femur to discuss the theoretical priority of these concepts. The current study investigated the angular relationship between the tibial attachment of the patellar tendon and the distal surface of the femur at 90° of flexion in normal knees. [Methods]The open magnetic resonance images of 45 normal knees at 90° of flexion were used to measure the angles between the tibial attachment of the patellar tendon, the equatorial line of the patella, and the distal surface of femoral condyles. [Results]The distal surface of femoral condyles was internally rotated relative to the tibial attachment of the patellar tendon and the equatorial line of the patella in all the knees (8.2° ± 3.5° and 5.8° ± 2.5°, respectively), not parallel. [Conclusions]Distal femoral condyle is internally rotated to the patellar tendon at 90° of flexion in normal knees. When the symmetric femoral component is aligned perpendicular to the femoral mechanical axis, the patellar tendon would be possibly more twisted than the condition in normal knees, and the deviation of the PF contact force on the patellar component might be caused. The configuration and alignment of the distal condyle of the femoral component can affect the PF joint congruity in knee flexion. In this respect, our results provide important information in considering designs and alignment in the distal femur of TKA and the PF joint congruity in knee flexion.en
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherBioMed Central Ltd.en
dc.rights© 2015 Kawahara et al.; licensee BioMed Central. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited.en
dc.subjectPatellofemoral (PF)en
dc.subjectThe tangent of the most distal part of femoral condylesen
dc.subjectThe tibial attachment of the patellar tendonen
dc.subjectMedially prominent femoral componenten
dc.subjectSymmetricen
dc.titleDistal femoral condyle is more internally rotated to the patellar tendon at 90° of flexion in normal knees.en
dc.typejournal article-
dc.type.niitypeJournal Article-
dc.identifier.jtitleJournal of Orthopaedic Surgery and Researchen
dc.identifier.volume10-
dc.relation.doi10.1186/s13018-015-0197-5-
dc.textversionpublisher-
dc.identifier.artnum54-
dc.identifier.pmid25906977-
dcterms.accessRightsopen access-
dc.identifier.eissn1749-799X-
出現コレクション:学術雑誌掲載論文等

アイテムの簡略レコードを表示する

Export to RefWorks


出力フォーマット 


このリポジトリに保管されているアイテムはすべて著作権により保護されています。