ダウンロード数: 199

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
jacmp.v16i4.5222.pdf761.15 kBAdobe PDF見る/開く
タイトル: Dosimetric evaluation of the Acuros XB algorithm for a 4MV photon beam in head and neck intensity-modulated radiation therapy
著者: Hirata, Kimiko
Nakamura, Mitsuhiro  kyouindb  KAKEN_id
Yoshimura, Michio  kyouindb  KAKEN_id  orcid https://orcid.org/0000-0001-6665-2245 (unconfirmed)
Mukumoto, Nobutaka  KAKEN_id  orcid https://orcid.org/0000-0002-4569-3379 (unconfirmed)
Nakata, Manabu
Ito, Hitoshi
Inokuchi, Haruo
Matsuo, Yukinori  KAKEN_id  orcid https://orcid.org/0000-0002-4372-8259 (unconfirmed)
Mizowaki, Takashi  kyouindb  KAKEN_id  orcid https://orcid.org/0000-0002-8135-8746 (unconfirmed)
Hiraoka, Masahiro
著者名の別形: 中村, 光弘
吉村, 通央
松尾, 幸憲
溝脇, 尚志
平岡, 眞寛
キーワード: Acuros XB algorithm
intensity-modulated radiation therapy
head and neck cancer
low-energy photon beam
heterogeneous media
発行日: 2015
出版者: American Association of Physicists in Medicine
誌名: Journal of Applied Clinical Medical Physics
巻: 16
号: 4
開始ページ: 52
終了ページ: 64
抄録: In this study, we assessed the differences in the dose distribution of a 4 MV photon beam among different calculation algorithms: the Acuros XB (AXB) algorithm, the analytic anisotropic algorithm (AAA), and the pencil beam convolution (PBC) algorithm (ver. 11.0.31), in phantoms and in clinical intensity-modulated radiation therapy (IMRT) plans. Homogeneous and heterogeneous, including middle-, low-, and high-density, phantoms were combined to assess the percentage depth dose and lateral dose profiles among AXB, AAA, and PBC. For the phantom containing the low-density area, AXB was in agreement with measurement within 0.5%, while the greatest differences between the AAA and PBC calculations and measurement were 2.7% and 3.6%, respectively. AXB showed agreement with measurement within 2.5% at the high-density area, while AAA and PBC overestimated the dose by more than 4.5% and 4.0%, respectively. Furthermore, 15 IMRT plans, calculated using AXB, for oropharyngeal, hypopharyngeal, and laryngeal carcinomas were analyzed. The dose prescription was 70 Gy to 50% of the planning target volume (PTV70). Subsequently, each plan was recalculated using AAA and PBC while maintaining the AXB-calculated monitor units, leaf motion, and beam arrangement. Additionally, nine hypopharyngeal and laryngeal cancer patients were analyzed in terms of PTV70 for cartilaginous structures (PTV70_cartilage). The doses covering 50% to PTV70 calculated by AAA and PBC were 2.1% ± 1.0% and 3.7% ± 0.8% significantly higher than those using AXB, respectively (p < 0.01). The increases in doses to PTV70_cartilage calculated by AAA and PBC relative to AXB were 3.9% and 5.3% on average, respectively, and were relatively greater than those in the entire PTV70. AXB was found to be in better agreement with measurement in phantoms in heterogeneous areas for the 4 MV photon beam. Considering AXB as the standard, AAA and PBC overestimated the IMRT dose for head and neck cancer. The dosimetric differences should not be ignored, particularly with cartilaginous structures in PTV.
著作権等: This work is licensed under a Creative Commons Attribution 3.0 License.
URI: http://hdl.handle.net/2433/216369
DOI(出版社版): 10.1120/jacmp.v16i4.5222
PubMed ID: 26218997
関連リンク: http://www.jacmp.org/index.php/jacmp/article/view/5222
出現コレクション:学術雑誌掲載論文等

アイテムの詳細レコードを表示する

Export to RefWorks


出力フォーマット 


このリポジトリに保管されているアイテムはすべて著作権により保護されています。