ダウンロード数: 223

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
S1600577516016362.pdf1.7 MBAdobe PDF見る/開く
完全メタデータレコード
DCフィールド言語
dc.contributor.authorHasegawa, Kazuyaen
dc.contributor.authorYamashita, Keitaroen
dc.contributor.authorMurai, Tomohiroen
dc.contributor.authorNuemket, Nipawanen
dc.contributor.authorHirata, Kunioen
dc.contributor.authorUeno, Goen
dc.contributor.authorAgo, Hideoen
dc.contributor.authorNakatsu, Toruen
dc.contributor.authorKumasaka, Takashien
dc.contributor.authorYamamoto, Masakien
dc.contributor.alternative長谷川, 和也ja
dc.contributor.alternative山下, 恵太郎ja
dc.contributor.alternative村井, 智洋ja
dc.contributor.alternativeニパワン, ヌアムケットja
dc.contributor.alternative平田, 邦生ja
dc.contributor.alternative上野, 剛ja
dc.contributor.alternative吾郷, 日出夫ja
dc.contributor.alternative中津, 亨ja
dc.contributor.alternative熊坂, 崇ja
dc.contributor.alternative山本, 雅貴ja
dc.date.accessioned2017-01-13T01:58:02Z-
dc.date.available2017-01-13T01:58:02Z-
dc.date.issued2017-01-
dc.identifier.issn1600-5775-
dc.identifier.urihttp://hdl.handle.net/2433/217787-
dc.description微小タンパク質結晶からの効率的な構造解析法 : 凍結した試料を回転させる「SS-ROX法」を確立、汎用化へ. 京都大学プレスリリース. 2017-01-12.ja
dc.description.abstractSerial crystallography, in which single-shot diffraction images are collected, has great potential for protein microcrystallography. Although serial femtosecond crystallography (SFX) has been successfully demonstrated, limited beam time prevents its routine use. Inspired by SFX, serial synchrotron crystallography (SSX) has been investigated at synchrotron macromolecular crystallography beamlines. Unlike SFX, the longer exposure time of milliseconds to seconds commonly used in SSX causes radiation damage. However, in SSX, crystals can be rotated during the exposure, which can achieve efficient coverage of the reciprocal space. In this study, mercury single-wavelength anomalous diffraction (Hg-SAD) phasing of the luciferin regenerating enzyme (LRE) was performed using serial synchrotron rotation crystallography. The advantages of rotation and influence of dose on the data collected were evaluated. The results showed that sample rotation was effective for accurate data collection, and the optimum helical rotation step depended on multiple factors such as multiplicity and partiality of reflections, exposure time per rotation angle and the contribution from background scattering. For the LRE microcrystals, 0.25° was the best rotation step for the achievable resolution limit, whereas a rotation step larger than or equal to 1° was favorable for Hg-SAD phasing. Although an accumulated dose beyond 1.1 MGy caused specific damage at the Hg site, increases in resolution and anomalous signal were observed up to 3.4 MGy because of a higher signal-to-noise ratio.en
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherInternational Union of Crystallographyen
dc.rightsThis is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.en
dc.subjectserial synchrotron crystallographyen
dc.subjectmercury single-wavelength anomalous diffractionen
dc.subjectradiation damageen
dc.titleDevelopment of a dose-limiting data collection strategy for serial synchrotron rotation crystallography.en
dc.typejournal article-
dc.type.niitypeJournal Article-
dc.identifier.jtitleJournal of synchrotron radiationen
dc.identifier.volume24-
dc.identifier.issuePt. 1-
dc.identifier.spage29-
dc.identifier.epage41-
dc.relation.doi10.1107/S1600577516016362-
dc.textversionpublisher-
dc.identifier.pmid28009544-
dc.relation.urlhttp://www.kyoto-u.ac.jp/ja/research/research_results/2016/161202_3.html-
dcterms.accessRightsopen access-
出現コレクション:学術雑誌掲載論文等

アイテムの簡略レコードを表示する

Export to RefWorks


出力フォーマット 


このリポジトリに保管されているアイテムはすべて著作権により保護されています。