ダウンロード数: 290
このアイテムのファイル:
ファイル | 記述 | サイズ | フォーマット | |
---|---|---|---|---|
1742-6596_573_1_012074.pdf | 948.18 kB | Adobe PDF | 見る/開く |
完全メタデータレコード
DCフィールド | 値 | 言語 |
---|---|---|
dc.contributor.author | Hayashi, Shin Ichiro | en |
dc.contributor.author | Sakurai, Yoshinori | en |
dc.contributor.author | Uchida, Ryohei | en |
dc.contributor.author | Suzuki, Minoru | en |
dc.contributor.author | Usui, Shuji | en |
dc.contributor.author | Tominaga, Takahiro | en |
dc.contributor.alternative | 櫻井, 良憲 | ja |
dc.contributor.alternative | 鈴木, 実 | ja |
dc.date.accessioned | 2017-05-25T07:29:08Z | - |
dc.date.available | 2017-05-25T07:29:08Z | - |
dc.date.issued | 2015-01-01 | - |
dc.identifier.issn | 1742-6596 | - |
dc.identifier.uri | http://hdl.handle.net/2433/224998 | - |
dc.description | 8th International Conference on 3D Radiation Dosimetry (IC3DDose) 4–7 September 2014, Ystad, Sweden | en |
dc.description.abstract | MAGAT gel dosimeter with boron is irradiated in Heavy Water Neutron Irradiation Facility (HWNIF) of Kyoto University Research Reactor (KUR). The cylindrical gel phantoms are exposed to neutron beams of three different energy spectra (thermal neutron rich, epithermal and fast neutron rich and the mixed modes) in air. Preliminary results corresponding to depth-dose responses are obtained as the transverse relaxation rate (R2=1/T2) from magnetic resonance imaging data. As the results MAGAT gel dosimeter has the higher sensitivity on thermal neutron than on epi-thermal and fast neutron, and the gel with boron showed an enhancement and a change in the depth-R2 response explicitly. From these results, it is suggested that MAGAT gel dosimeter can be an effective tool in BNCT dosimetry. | en |
dc.format.mimetype | application/pdf | - |
dc.language.iso | eng | - |
dc.publisher | Institute of Physics Publishing | en |
dc.rights | Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI. Published under licence by IOP Publishing Ltd. | en |
dc.title | Preliminary study of MAGAT polymer gel dosimetry for boron-neutron capture therapy | en |
dc.type | conference paper | - |
dc.type.niitype | Conference Paper | - |
dc.identifier.jtitle | Journal of Physics: Conference Series | en |
dc.identifier.volume | 573 | - |
dc.relation.doi | 10.1088/1742-6596/573/1/012074 | - |
dc.textversion | publisher | - |
dc.identifier.artnum | 012074 | - |
dcterms.accessRights | open access | - |
出現コレクション: | 学術雑誌掲載論文等 |
このリポジトリに保管されているアイテムはすべて著作権により保護されています。