このアイテムのアクセス数: 206

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
s13047-017-0199-0.pdf2.25 MBAdobe PDF見る/開く
完全メタデータレコード
DCフィールド言語
dc.contributor.authorSaeki, Junyaen
dc.contributor.authorIkezoe, Tomeen
dc.contributor.authorNakamura, Masatoshien
dc.contributor.authorNishishita, Satoruen
dc.contributor.authorIchihashi, Noriakien
dc.contributor.alternative佐伯, 純弥ja
dc.contributor.alternative池添, 冬芽ja
dc.contributor.alternative西下, 智ja
dc.contributor.alternative市橋, 則明ja
dc.date.accessioned2017-06-08T04:29:13Z-
dc.date.available2017-06-08T04:29:13Z-
dc.date.issued2017-04-18-
dc.identifier.issn1757-1146-
dc.identifier.urihttp://hdl.handle.net/2433/225248-
dc.description.abstract[Background]Excessive stiffness of lower limb muscles is associated with sports injuries. Therefore, the identification of a reliable measurement of the shear elastic modulus of various ankle plantar flexion muscles is required to evaluate lower leg sports injuries. This study investigated the reliable measurement of the shear elastic modulus of the ankle plantar flexion muscles at different ankle positions. [Methods]Twenty-three healthy young men (25.3 ± 3.6 years, 172.9 ± 5.0 cm, 67.2 ± 7.2 kg) participated in this study. The shear elastic moduli of the ankle plantar flexion muscles including the lateral gastrocnemius, medial gastrocnemius, soleus, peroneus longus, peroneus brevis, flexor hallucis longus, flexor digitorum longus and tibialis posterior were measured using ultrasonic shear wave elastography at 0, 10 and 20° dorsiflexion. [Results]The reliability of the shear elastic modulus measurements for each ankle position was assessed. The results showed that the interday reliability of the measurements differed between ankle positions and that the reliability of the shear elastic modulus measurements at 20° dorsiflexion was higher than that at 10° or 0°. [Conclusion]Our results suggest that measurements at 20° dorsiflexion may provide a more reliable measurement of the shear elastic modulus of ankle plantar flexion muscles.en
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherSpringer Natureen
dc.rights© The Author(s). 2017 This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.en
dc.subjectShear-wave elastographyen
dc.subjectShear elastic modulusen
dc.subjectMuscle stiffnessen
dc.subjectMuscle hardnessen
dc.subjectReliabilityen
dc.subjectTibialis posterioren
dc.subjectFlexor digitorum longusen
dc.subjectFlexor hallucis longusen
dc.titleThe reliability of shear elastic modulus measurement of the ankle plantar flexion muscles is higher at dorsiflexed position of the ankleen
dc.typejournal article-
dc.type.niitypeJournal Article-
dc.identifier.jtitleJournal of Foot and Ankle Researchen
dc.identifier.volume10-
dc.relation.doi10.1186/s13047-017-0199-0-
dc.textversionpublisher-
dc.identifier.artnum18-
dc.identifier.pmid28428826-
dcterms.accessRightsopen access-
出現コレクション:学術雑誌掲載論文等

アイテムの簡略レコードを表示する

Export to RefWorks


出力フォーマット 


このリポジトリに保管されているアイテムはすべて著作権により保護されています。