このアイテムのアクセス数: 291

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
2046-3758.61.BJR-2016-0090.R1.pdf1.72 MBAdobe PDF見る/開く
完全メタデータレコード
DCフィールド言語
dc.contributor.authorNakamura, S.en
dc.contributor.authorTian, Y.en
dc.contributor.authorTanaka, Y.en
dc.contributor.authorKuriyama, S.en
dc.contributor.authorIto, H.en
dc.contributor.authorFuru, M.en
dc.contributor.authorMatsuda, S.en
dc.contributor.alternative中村, 伸一郎ja
dc.contributor.alternative栗山, 新一ja
dc.contributor.alternative伊藤, 宣ja
dc.contributor.alternative布留, 守敏ja
dc.contributor.alternative松田, 秀一ja
dc.date.accessioned2017-10-20T03:03:31Z-
dc.date.available2017-10-20T03:03:31Z-
dc.date.issued2017-01-11-
dc.identifier.issn2046-3758-
dc.identifier.urihttp://hdl.handle.net/2433/227676-
dc.description.abstractObjectives: Little biomechanical information is available about kinematically aligned (KA) total knee arthroplasty (TKA). The purpose of this study was to simulate the kinematics and kinetics after KA TKA and mechanically aligned (MA) TKA with four different limb alignments. Materials and Methods: Bone models were constructed from one volunteer (normal) and three patients with three different knee deformities (slight, moderate and severe varus). A dynamic musculoskeletal modelling system was used to analyse the kinematics and the tibiofemoral contact force. The contact stress on the tibial insert, and the stress to the resection surface and medial tibial cortex were examined by using finite element analysis. Results: In all bone models, posterior translation on the lateral side and external rotation in the KA TKA models were greater than in the MA TKA models. The tibiofemoral force at the medial side was increased in the moderate and severe varus models with KA TKA. In the severe varus model with KA TKA, the contact stress on the tibial insert and the stress to the resection surface and to the medial tibial cortex were increased by 41.5%, 32.2% and 53.7%, respectively, compared with MA TKA, and the bone strain at the medial side was highest among all models. Conclusion: Near normal kinematics was observed in KA TKA. However, KA TKA increased the contact force, stress and bone strain at the medial side for moderate and severe varus knee models. The application of KA TKA for severe varus knees may be inadequate.en
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherBritish Editorial Society of Bone and Joint Surgeryen
dc.rights© 2017 Nakamura et al.en
dc.rightsThis is an open-access article distributed under the terms of the Creative Commons Attributions licence (CC-BY-NC), which permits unrestricted use, distribution, and reproduction in any medium, but not for commercial gain, provided the original author and source are credited.en
dc.subjectTotal knee arthroplastyen
dc.subjectKinematic alignmenten
dc.subjectContact stressen
dc.subjectFinite element analysisen
dc.subjectComputer simulationen
dc.titleThe effects of kinematically aligned total knee arthroplasty on stress at the medial tibia: A case study for varus kneeen
dc.typejournal article-
dc.type.niitypeJournal Article-
dc.identifier.jtitleBone and Joint Researchen
dc.identifier.volume6-
dc.identifier.spage43-
dc.identifier.epage51-
dc.relation.doi10.1302/2046-3758.61.BJR-2016-0090.R1-
dc.textversionpublisher-
dc.identifier.pmid28077396-
dcterms.accessRightsopen access-
出現コレクション:学術雑誌掲載論文等

アイテムの簡略レコードを表示する

Export to RefWorks


出力フォーマット 


このリポジトリに保管されているアイテムはすべて著作権により保護されています。