ダウンロード数: 159

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
jrr_rry064.pdf442.79 kBAdobe PDF見る/開く
完全メタデータレコード
DCフィールド言語
dc.contributor.authorUto, Megumien
dc.contributor.authorMizowaki, Takashien
dc.contributor.authorOgura, Kengoen
dc.contributor.authorMukumoto, Nobutakaen
dc.contributor.authorKatagiri, Tomohiroen
dc.contributor.authorTakehana, Keiichien
dc.contributor.authorHiraoka, Masahiroen
dc.contributor.alternative宇藤, 恵ja
dc.contributor.alternative溝脇, 尚志ja
dc.contributor.alternative小倉, 健吾ja
dc.contributor.alternative片桐, 幸大ja
dc.contributor.alternative平岡, 眞寛ja
dc.date.accessioned2018-12-04T04:22:27Z-
dc.date.available2018-12-04T04:22:27Z-
dc.date.issued2018-11-
dc.identifier.issn1349-9157-
dc.identifier.urihttp://hdl.handle.net/2433/235516-
dc.description.abstractMono-isocentric volumetric-modulated arc therapy (VMAT) can be used to treat multiple brain metastases. It remains unknown whether mono-isocentric VMAT can improve the dose distribution compared with dual-isocentric dynamic conformal arc therapy (DCAT), especially for two brain metastases. We compared the dose distribution between dual-isocentric DCAT and mono-isocentric VMAT for two large brain metastases, and analyzed the relationship between the distance between the two targets and the difference in dose distribution. A total of 19 patients, each with two large brain metastases, were enrolled. The dose prescribed for each planning target volume (PTV) was 28 Gy in five fractions (D99.8 = 100%). We created new indices derived from conformity indices suggested by the Radiation Therapy Oncology Group (RTOG; mRTOG-CI) and Paddick et al. (mIP-CI), using the dosimetric parameters of the sum of the two PTVs. The median PTV was 5.05 cm³ (range, 2.10–28.47). VMAT significantly improved mRTOG-CI and mIP-CI compared with DCAT. In all cases, VMAT was able to improve mRTOG-CI and mIP-CI compared with DCAT. Whereas the normal brain volume receiving 5 Gy was similar between the two modalities, the normal brain receiving 10, 12, 15, 20, 25 and 28 Gy (V₁₀-V₂₈) was significantly smaller in VMAT. The mean beam-on times were 213.3 s and 121.9 s in DCAT and VMAT, respectively (P < 0.001). Mono-isocentric VMAT improved the target conformity and reduced the beam-on time and V₁₀-V₂₈ of the normal brain for not only two close metastases but also two distant metastases. Mono-isocentric VMAT seems to be a promising treatment technique for two large brain metastases.en
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherOxford University Press (OUP)en
dc.rights© The Author(s) 2018. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology. This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.comen
dc.subjectdynamic conformal arc therapyen
dc.subjectvolumetric-modulated arc therapyen
dc.subjecttwo brain metastasesen
dc.subjectdosimetric comparisonen
dc.titleDosimetric comparison between dual-isocentric dynamic conformal arc therapy and mono-isocentric volumetric-modulated arc therapy for two large brain metastasesen
dc.typejournal article-
dc.type.niitypeJournal Article-
dc.identifier.jtitleJournal of radiation researchen
dc.identifier.volume59-
dc.identifier.issue6-
dc.identifier.spage774-
dc.identifier.epage781-
dc.relation.doi10.1093/jrr/rry064-
dc.textversionpublisher-
dc.addressDepartment of Radiation Oncology and Image-applied Therapy, Kyoto University Graduate School of Medicineen
dc.addressDepartment of Radiation Oncology and Image-applied Therapy, Kyoto University Graduate School of Medicineen
dc.addressDepartment of Radiation Oncology and Image-applied Therapy, Kyoto University Graduate School of Medicineen
dc.addressDepartment of Radiation Oncology and Image-applied Therapy, Kyoto University Graduate School of Medicineen
dc.addressDepartment of Radiation Oncology and Image-applied Therapy, Kyoto University Graduate School of Medicineen
dc.addressDepartment of Radiation Oncology and Image-applied Therapy, Kyoto University Graduate School of Medicineen
dc.addressDepartment of Radiation Oncology and Image-applied Therapy, Kyoto University Graduate School of Medicineen
dc.identifier.pmid30102325-
dcterms.accessRightsopen access-
出現コレクション:学術雑誌掲載論文等

アイテムの簡略レコードを表示する

Export to RefWorks


出力フォーマット 


このリポジトリに保管されているアイテムはすべて著作権により保護されています。