ダウンロード数: 61

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
j.ejro.2019.02.001.pdf2.8 MBAdobe PDF見る/開く
タイトル: Efficiency and reproducibility in pulmonary nodule detection in simulated dose reduction lung CT images
著者: Kubo, Takeshi  KAKEN_id
Ohno Kishimoto, Ayami
Togashi, Kaori
著者名の別形: 久保, 武
大野, 文美
富樫, かおり
キーワード: Computed tomography
Radiation dose reduction
Automatic exposure control
Pulmonary nodules
発行日: 2019
出版者: Elsevier BV
誌名: European Journal of Radiology Open
巻: 6
開始ページ: 113
終了ページ: 118
抄録: Purpose: To determine the reproducibility and productivity of reduced dose chest computed tomography (CT) using a nodule detection task. Materials and methods: Eighty-eight consecutive non-contrast CT examinations were performed using an automatic exposure system with a reference standard deviation of 8.5. Simulated raw data of a reduced dose scan (standard deviation at 21 and 29) were generated with a dose simulator. Original and simulated raw data were reconstructed to series of 7-mm-thick images (Original, Simulation A, Simulation B). In the first part of the reading experiment, three readers independently interpreted these images (88 cases × 3 series) and recorded the size, type, and location of the pulmonary nodules. The reading time for every case was recorded. In the second part of the experiment, the repeated interpretation of standard dose images was performed by two readers. Concordance or discordance of nodule detection between the first and the repeated reading result was assessed. Results: A statistically significant difference in the detected nodule counts for lesions less than 5 mm by one reader was observed in simulation B images. Discordance of the interpretation result was found only in ground-glass nodules larger than 5 mm detected by one reader in simulation B images. There was no statistically significant difference in the reading time among the three image types. Conclusion: Simulated standard deviation 21 images can reproduce the image interpretation result of original images, whereas simulated standard deviation 29 images may compromise the accuracy of nodule assessment. The effect on the reading time was not observed with dose reduction simulation.
著作権等: © 2019 Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/BY-NC-ND/4.0/).
URI: http://hdl.handle.net/2433/237329
DOI(出版社版): 10.1016/j.ejro.2019.02.001
PubMed ID: 30899771
出現コレクション:学術雑誌掲載論文等

アイテムの詳細レコードを表示する

Export to RefWorks


出力フォーマット 


このリポジトリに保管されているアイテムはすべて著作権により保護されています。