ダウンロード数: 288

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
s00330-018-5862-8.pdf1.71 MBAdobe PDF見る/開く
完全メタデータレコード
DCフィールド言語
dc.contributor.authorOkuchi, Sachien
dc.contributor.authorFushimi, Yasutakaen
dc.contributor.authorOkada, Tomohisaen
dc.contributor.authorYamamoto, Akiraen
dc.contributor.authorOkada, Tsutomuen
dc.contributor.authorKikuchi, Takayukien
dc.contributor.authorYoshida, Kazumichien
dc.contributor.authorMiyamoto, Susumuen
dc.contributor.authorTogashi, Kaorien
dc.contributor.alternative奥知, 左智ja
dc.contributor.alternative伏見, 育崇ja
dc.contributor.alternative岡田, 知久ja
dc.contributor.alternative山本, 憲ja
dc.contributor.alternative岡田, 務ja
dc.contributor.alternative菊池, 隆幸ja
dc.contributor.alternative吉田, 和道ja
dc.contributor.alternative宮本, 享ja
dc.contributor.alternative富樫, かおりja
dc.date.accessioned2019-07-11T06:36:31Z-
dc.date.available2019-07-11T06:36:31Z-
dc.date.issued2019-08-
dc.identifier.issn0938-7994-
dc.identifier.issn1432-1084-
dc.identifier.urihttp://hdl.handle.net/2433/242961-
dc.description.abstract[Objectives]To compare visualization of carotid plaques and vessel walls between 3D T₁-fast spin echo imaging with conventional SPACE (T₁-SPACE) and with a prototype compressed sensing T₁-SPACE (CS-T₁-SPACE) [Methods]This retrospective study was approved by the institutional review board. Participants comprised 43 patients (36 males, 7 females; mean age, 71 years) who underwent carotid MRI including T₁-SPACE and CS-T₁-SPACE. The quality of visualization for carotid plaques and vessel walls was evaluated using a 5-point scale, and signal intensity ratios (SRs) of the carotid plaques were measured and normalized to the adjacent sternomastoid muscle. Scores for the quality of visualization were compared between T₁-SPACE and CS-T₁-SPACE using the Wilcoxon signed-rank test. Statistical differences between SRs of plaques with T₁-SPACE and CS-T₁-SPACE were also evaluated using the Wilcoxon signed-rank test, and Spearman’s correlation coefficient was calculated to investigate correlations. [Results]Visualization scores were significantly higher for CS-T₁-SPACE than for T₁-SPACE when evaluating carotid plaques (p = 0.0212) and vessel walls (p < 0.001). The SR of plaques did not differ significantly between T₁-SPACE and CS-T₁-SPACE (p = 0.5971). Spearman’s correlation coefficient was significant (0.884; p < 0.0001). [Conclusions]CS-T₁-SPACE allowed better visualization scores and sharpness compared with T₁-SPACE in evaluating carotid plaques and vessel walls, with a 2.5-fold accelerated scan time with comparable image quality. CS-T₁-SPACE appears promising as a method for investigating carotid vessel walls, offering better image quality with a shorter acquisition time.en
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherSpringer Berlin Heidelbergen
dc.rightsThis is a post-peer-review, pre-copyedit version of an article published in 'European Radiology'. The final authenticated version is available online at: https://doi.org/10.1007/s00330-018-5862-8en
dc.rightsThe full-text file will be made open to the public on 06 December 2019 in accordance with publisher's 'Terms and Conditions for Self-Archiving'en
dc.rightsThis is not the published version. Please cite only the published version.en
dc.rightsこの論文は出版社版でありません。引用の際には出版社版をご確認ご利用ください。ja
dc.subjectMagnetic resonance imagingen
dc.subjectCarotid stenosisen
dc.subjectAtherosclerosisen
dc.subjectArtifactsen
dc.subjectImage reconstructionen
dc.titleVisualization of carotid vessel wall and atherosclerotic plaque: T₁-SPACE vs. compressed sensing T₁-SPACEen
dc.typejournal article-
dc.type.niitypeJournal Article-
dc.identifier.jtitleEuropean Radiology-
dc.identifier.volume29-
dc.identifier.issue8-
dc.identifier.spage4114-
dc.identifier.epage4122-
dc.relation.doi10.1007/s00330-018-5862-8-
dc.textversionauthor-
dc.addressDepartment of Diagnostic Imaging and Nuclear MedicineKyoto University Graduate School of Medicineen
dc.addressDepartment of Diagnostic Imaging and Nuclear MedicineKyoto University Graduate School of Medicineen
dc.addressHuman Brain Research CenterKyoto University Graduate School of Medicineen
dc.addressDepartment of Diagnostic Imaging and Nuclear MedicineKyoto University Graduate School of Medicineen
dc.addressDepartment of Diagnostic Imaging and Nuclear MedicineKyoto University Graduate School of Medicineen
dc.addressDepartment of NeurosurgeryKyoto University Graduate School of Medicineen
dc.addressDepartment of NeurosurgeryKyoto University Graduate School of Medicineen
dc.addressDepartment of NeurosurgeryKyoto University Graduate School of Medicineen
dc.addressDepartment of Diagnostic Imaging and Nuclear MedicineKyoto University Graduate School of Medicineen
dc.identifier.pmid30523455-
dcterms.accessRightsopen access-
datacite.date.available2019-12-06-
datacite.awardNumber18K07711-
jpcoar.funderName日本学術振興会ja
jpcoar.funderName.alternativeJapan Society for the Promotion of Science (JSPS)en
出現コレクション:学術雑誌掲載論文等

アイテムの簡略レコードを表示する

Export to RefWorks


出力フォーマット 


このリポジトリに保管されているアイテムはすべて著作権により保護されています。