ダウンロード数: 109

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
j.ejro.2018.01.003.pdf694.82 kBAdobe PDF見る/開く
完全メタデータレコード
DCフィールド言語
dc.contributor.authorIima, Mamien
dc.contributor.authorKataoka, Masakoen
dc.contributor.authorSakaguchi, Renaen
dc.contributor.authorKanao, Shotaroen
dc.contributor.authorOnishi, Natsukoen
dc.contributor.authorKawai, Makikoen
dc.contributor.authorOhashi, Akaneen
dc.contributor.authorMurata, Katsutoshien
dc.contributor.authorTogashi, Kaorien
dc.contributor.alternative飯間, 麻美ja
dc.contributor.alternative片岡, 正子ja
dc.contributor.alternative金尾, 昌太郎ja
dc.contributor.alternative大西, 奈都子ja
dc.contributor.alternative河合, 真喜子ja
dc.contributor.alternative大橋, 茜ja
dc.contributor.alternative村田, 勝俊ja
dc.contributor.alternative富樫, かおりja
dc.date.accessioned2020-03-26T06:41:47Z-
dc.date.available2020-03-26T06:41:47Z-
dc.date.issued2018-
dc.identifier.issn2352-0477-
dc.identifier.urihttp://hdl.handle.net/2433/246439-
dc.description.abstractPurpose: To investigate the effect of breastfeeding on IVIM and non-Gaussian diffusion MRI in the breast. Materials and methods: An IRB approved prospective study enrolled seventeen volunteers (12 in lactation and 5 with post-weaning, range 31–43 years; mean 35.4 years). IVIM (fIVIM and D*) and non-Gaussian diffusion (ADC₀ and K) parameters using 16 b values, plus synthetic apparent diffusion coefficients (sADCs) from 2 key b values (b = 200 and 1500 s/mm²) were calculated using regions of interest. ADC₀ maps of the whole breast were generated and their contrast patterns were evaluated by two independent readers using retroareolar and segmental semi-quantitative scores. To compare the diffusion and IVIM parameters, Wilcoxon signed rank tests were used between pre- and post-breastfeeding and Mann-Whitney tests were used between post-weaning and pre- or post-breastfeeding. Results: ADC₀ and sADC values significantly decreased post-breastfeeding (1.90 vs. 1.72 × 10⁻³mn²/s, P < 0.001) while K values significantly increased (0.33 vs. 0.44, P < 0.05). fIVIM values significantly increased after breastfeeding (1.97 vs. 2.97%, P < 0.01). No significant difference was found in D* values. There was significant heterogeneity in ADC₀ maps post-breastfeeding, both in retroareolar and segmental scores (P < 0.0001 and =0.0001). Conclusion: IVIM and non-Gaussian diffusion parameters significantly changed between pre- and post-breastfeeding status, and care needs to be taken in interpreting diffusion-weighted imaging (DWI) data in lactating breasts.en
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherElsevier BVen
dc.rights© 2018 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/BY-NC-ND/4.0/).en
dc.subjectDiffusion-weighted imagingen
dc.subjectIntravoxel incoherent motionen
dc.subjectKurtosisen
dc.subjectLactationen
dc.subjectBreasten
dc.titleIntravoxel incoherent motion (IVIM) and non-Gaussian diffusion MRI of the lactating breasten
dc.typejournal article-
dc.type.niitypeJournal Article-
dc.identifier.jtitleEuropean Journal of Radiology Openen
dc.identifier.volume5-
dc.identifier.spage24-
dc.identifier.epage30-
dc.relation.doi10.1016/j.ejro.2018.01.003-
dc.textversionpublisher-
dc.addressDepartment of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine・The Hakubi Center for Advanced Research, Kyoto Universityen
dc.addressDepartment of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicineen
dc.addressDepartment of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicineen
dc.addressDepartment of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicineen
dc.addressDepartment of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicineen
dc.addressDepartment of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicineen
dc.addressDepartment of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicineen
dc.addressSiemens Japan K.K.en
dc.addressDepartment of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicineen
dc.identifier.pmid29719854-
dcterms.accessRightsopen access-
datacite.awardNumber15K19786-
jpcoar.funderName日本学術振興会ja
jpcoar.funderName.alternativeJapan Society for the Promotion of Science (JSPS)en
出現コレクション:学術雑誌掲載論文等

アイテムの簡略レコードを表示する

Export to RefWorks


出力フォーマット 


このリポジトリに保管されているアイテムはすべて著作権により保護されています。