このアイテムのアクセス数: 466

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
jmri.26962.pdf4.01 MBAdobe PDF見る/開く
タイトル: Evaluation of image quality of pituitary dynamic contrast-enhanced MRI using time-resolved angiography with interleaved stochastic trajectories (TWIST) and iterative reconstruction TWIST (IT-TWIST)
著者: Yokota, Yusuke
Fushimi, Yasutaka  kyouindb  KAKEN_id  orcid https://orcid.org/0000-0002-1982-3168 (unconfirmed)
Okada, Tomohisa  kyouindb  KAKEN_id  orcid https://orcid.org/0000-0001-5088-4017 (unconfirmed)
Fujimoto, Koji  kyouindb  KAKEN_id  orcid https://orcid.org/0000-0003-1209-7949 (unconfirmed)
Oshima, Sonoko
Nakajima, Satoshi  kyouindb  KAKEN_id  orcid https://orcid.org/0000-0001-5088-4017 (unconfirmed)
Fujii, Toshihito  KAKEN_id
Tanji, Masahiro
Inagaki, Nobuya  KAKEN_id
Miyamoto, Susumu
Togashi, Kaori
著者名の別形: 伏見, 育崇
岡田, 知久
藤本, 晃司
中島, 諭
藤井, 寿人
丹治, 正大
稲垣, 暢也
宮本, 享
富樫, かおり
キーワード: magnetic resonance imaging
pituitary gland
central nervous system
発行日: May-2020
出版者: Wiley
誌名: Journal of magnetic resonance imaging : JMRI
巻: 51
号: 5
開始ページ: 1497
終了ページ: 1506
抄録: Background: Time‐resolved angiography with interleaved stochastic trajectories (TWIST) is a keyhole imaging with frequent sampling of central k‐space data and view‐sharing for the peripheral k‐space of dynamic phases. IT‐TWIST is a technique to reconstruct images with a smaller temporal footprint using the same raw data obtained with TWIST by iterative reconstruction. Purpose: To compare image quality between TWIST and IT‐TWIST in 3D pituitary DCE‐MRI. Study Type: Retrospective observation study. Population: Fifty‐one patients (23 men, 28 women) who underwent 3D pituitary DCE‐MRI using TWIST between July 2016 and April 2017. Field Strength/Sequence: 3T/TWIST and IT‐TWIST. Assessment: Visual evaluation was conducted for image quality of delineation of the pituitary stalk and posterior lobe during the early arterial phase, cerebral white matter near the sella turcica, and the mass lesion. Bolus sharpness of the pituitary stalk, posterior lobe, and bilateral cavernous sinus was evaluated on the enhancement slope map calculated from TWIST and IT‐TWIST. Temporal stability of intensity of the nonenhanced area was evaluated on temporal standard deviation (SD) maps calculated from TWIST and IT‐TWIST. Statistical Tests: Paired t‐test or Wilcoxon rank‐sum test was used to test the differences between TWIST and IT‐TWIST in both visual evaluation and region of interest evaluation. Results: Scores of visual evaluations for IT‐TWIST were significantly better than those for TWIST (P < 0.001) in all items. Enhancement slope for IT‐TWIST was significantly higher than that for TWIST in posterior lobe, and right and left cavernous sinus (P < 0.001). Temporal SD for IT‐TWIST was significantly lower than that for TWIST in all items, with statistical significance (P < 0.001). Data Conclusion: IT‐TWIST yielded better visualization, and better enhancement slope, and less temporal SD compared with TWIST in 3D pituitary DCE‐MRI.
著作権等: This is the peer reviewed version of the following article: [Journal of magnetic resonance imaging : JMRI, 51(5), 1497-1506], which has been published in final form at https://doi.org/10.1002/jmri.26962. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions.
The full-text file will be made open to the public on 18 October 2020 in accordance with publisher's 'Terms and Conditions for Self-Archiving'
This is not the published version. Please cite only the published version.
この論文は出版社版でありません。引用の際には出版社版をご確認ご利用ください。
URI: http://hdl.handle.net/2433/250494
DOI(出版社版): 10.1002/jmri.26962
PubMed ID: 31625655
出現コレクション:学術雑誌掲載論文等

アイテムの詳細レコードを表示する

Export to RefWorks


出力フォーマット 


このリポジトリに保管されているアイテムはすべて著作権により保護されています。