dc.contributor.authorManohar, Rutvikaen
dc.contributor.authorHikihara, Takashien
dc.contributor.alternative引原, 隆士ja
dc.date.accessioned2020-06-12T07:38:29Z-
dc.date.available2020-06-12T07:38:29Z-
dc.date.issued2020-06-
dc.identifier.issn0098-9886-
dc.identifier.issn1097-007X-
dc.identifier.urihttp://hdl.handle.net/2433/251421-
dc.description.abstractThis paper discusses a ring‐coupled buck‐type inverter system to harness energy from direct current (DC) sources of electricity. The DC‐DC buck converter circuit is modified with an H‐bridge to convert the DC input voltage to a usable alternating current (AC) output voltage. Passivity‐based control (PBC) with port‐controlled Hamiltonian modelling (PCHM) is a method where the system is controlled by considering not only the energy properties of the system but also the inherent physical structure. PBC is applied to achieve stabilization of the AC output voltage to a desired amplitude and frequency. Unsynchronized output voltages in terms of phase angle or frequency can cause detrimental effects on the system. Phase‐locked loop (PLL) is employed in the ring structure to maintain synchronization of the AC output voltage of all inverter units in the ring‐coupled system.en
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherWileyen
dc.rightsThis is the peer reviewed version of the following article: Manohar, R, Hikihara, T. Phase synchronization of autonomous AC grid system with passivity‐based control. Int J Circ Theor Appl. 2020; 48: 906– 918, which has been published in final form at https://doi.org/10.1002/cta.2760. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions.en
dc.rightsThe full-text file will be made open to the public on 4 March 2021 in accordance with publisher's 'Terms and Conditions for Self-Archiving'.en
dc.rightsThis is not the published version. Please cite only the published version.en
dc.rightsこの論文は出版社版でありません。引用の際には出版社版をご確認ご利用ください。ja
dc.subjectbuck-type inverteren
dc.subjectdistributed generationen
dc.subjectpassivity-based controlen
dc.subjectring-coupled systemen
dc.subjectsynchronizationen
dc.titlePhase synchronization of autonomous AC grid system with passivity-based controlen
dc.typejournal article-
dc.type.niitypeJournal Article-
dc.identifier.jtitleInternational Journal of Circuit Theory and Applicationsen
dc.identifier.volume48-
dc.identifier.issue6-
dc.identifier.spage906-
dc.identifier.epage918-
dc.relation.doi10.1002/cta.2760-
dc.textversionauthor-
dc.addressDepartment of Electrical Engineering, Kyoto Universityen
dc.addressDepartment of Electrical Engineering, Kyoto Universityen
dcterms.accessRightsopen access-
datacite.date.available2021-03-04-
dc.identifier.pissn0098-9886-
dc.identifier.eissn1097-007X-
出現コレクション:学術雑誌掲載論文等

アイテムの簡略レコードを表示する

Export to RefWorks


出力フォーマット 


このリポジトリに保管されているアイテムはすべて著作権により保護されています。