dc.contributor.author | Manohar, Rutvika | en |
dc.contributor.author | Hikihara, Takashi | en |
dc.contributor.alternative | 引原, 隆士 | ja |
dc.date.accessioned | 2020-06-12T07:38:29Z | - |
dc.date.available | 2020-06-12T07:38:29Z | - |
dc.date.issued | 2020-06 | - |
dc.identifier.issn | 0098-9886 | - |
dc.identifier.issn | 1097-007X | - |
dc.identifier.uri | http://hdl.handle.net/2433/251421 | - |
dc.description.abstract | This paper discusses a ring‐coupled buck‐type inverter system to harness energy from direct current (DC) sources of electricity. The DC‐DC buck converter circuit is modified with an H‐bridge to convert the DC input voltage to a usable alternating current (AC) output voltage. Passivity‐based control (PBC) with port‐controlled Hamiltonian modelling (PCHM) is a method where the system is controlled by considering not only the energy properties of the system but also the inherent physical structure. PBC is applied to achieve stabilization of the AC output voltage to a desired amplitude and frequency. Unsynchronized output voltages in terms of phase angle or frequency can cause detrimental effects on the system. Phase‐locked loop (PLL) is employed in the ring structure to maintain synchronization of the AC output voltage of all inverter units in the ring‐coupled system. | en |
dc.format.mimetype | application/pdf | - |
dc.language.iso | eng | - |
dc.publisher | Wiley | en |
dc.rights | This is the peer reviewed version of the following article: Manohar, R, Hikihara, T. Phase synchronization of autonomous AC grid system with passivity‐based control. Int J Circ Theor Appl. 2020; 48: 906– 918, which has been published in final form at https://doi.org/10.1002/cta.2760. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions. | en |
dc.rights | The full-text file will be made open to the public on 4 March 2021 in accordance with publisher's 'Terms and Conditions for Self-Archiving'. | en |
dc.rights | This is not the published version. Please cite only the published version. | en |
dc.rights | この論文は出版社版でありません。引用の際には出版社版をご確認ご利用ください。 | ja |
dc.subject | buck-type inverter | en |
dc.subject | distributed generation | en |
dc.subject | passivity-based control | en |
dc.subject | ring-coupled system | en |
dc.subject | synchronization | en |
dc.title | Phase synchronization of autonomous AC grid system with passivity-based control | en |
dc.type | journal article | - |
dc.type.niitype | Journal Article | - |
dc.identifier.jtitle | International Journal of Circuit Theory and Applications | en |
dc.identifier.volume | 48 | - |
dc.identifier.issue | 6 | - |
dc.identifier.spage | 906 | - |
dc.identifier.epage | 918 | - |
dc.relation.doi | 10.1002/cta.2760 | - |
dc.textversion | author | - |
dc.address | Department of Electrical Engineering, Kyoto University | en |
dc.address | Department of Electrical Engineering, Kyoto University | en |
dcterms.accessRights | open access | - |