このアイテムのアクセス数: 193

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
aja.201909_57(3).0005.pdf703.19 kBAdobe PDF見る/開く
完全メタデータレコード
DCフィールド言語
dc.contributor.authorMizota, Toshiyukien
dc.contributor.authorKohara, Jumpeien
dc.contributor.authorGoto, Wataruen
dc.contributor.authorShiraki, Atsukoen
dc.contributor.authorDong, Lien
dc.contributor.authorTakeda, Chikashien
dc.contributor.authorFukagawa, Hiroshien
dc.contributor.alternative溝田, 敏幸ja
dc.contributor.alternative小原, 淳平ja
dc.contributor.alternative後藤, 渉ja
dc.contributor.alternative白木, 敦子ja
dc.contributor.alternative董, 理ja
dc.contributor.alternative武田, 親宗ja
dc.contributor.alternative深川, 博志ja
dc.date.accessioned2020-09-18T02:40:36Z-
dc.date.available2020-09-18T02:40:36Z-
dc.date.issued2019-09-
dc.identifier.issn2468-824X-
dc.identifier.urihttp://hdl.handle.net/2433/254483-
dc.description.abstractObjective: The Radford nomogram, an old mathematical chart device to estimate the required ventilation for maintaining normocapnia, remains unvalidated in patients undergoing modern, balanced anesthesia. This study aims to investigate the performance of the Radford nomogram in patients undergoing general anesthesia and derive a simple equation to estimate the minute volume required to attain normocapnia (MVnorm). Methods: This single-center retrospective study enrolled 78 patients (age ≥ 18 years) undergoing cerebral revascularization for Moyamoya disease. We defi ned MVnorm as the median of all values of the minute volume during normocapnia (estimated PaCO2: 38–42 mmHg). We examined the agreement level between the estimated minute volume using the Radford nomogram and MVnorm using the Bland–Altman analysis. Furthermore, we developed and validated a simple equation predicting MVnorm based on gender and a multiple of body weight, using a split-sample validation technique. Result: The Radford nomogram tended to overestimate MVnorm with a mean bias of 560 mL/min (95% limits of agreement, -848–1, 968 mL/min). The equation developed using data from the development group (n = 52): required minute volume (mL/min) = 85 × body weight (kg) in male patients and 70 × body weight (kg) in female patients. In the validation group (n = 26), the mean bias of this simple equation was 224 mL/min (95% limits of agreement, -1, 264–1, 712 mL/min). Conclusion: The Radford nomogram overestimates MVnorm in modern, balanced anesthesia. The simple equation using gender and a multiple of body weight yields similar predictive performance to the Radford nomogram.en
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherThe Taiwan Society of Anaesthesiologistsen
dc.publisher.alternative台灣麻醉醫學會zh-tw
dc.rightsThis journal is a peer reviewed, subsidized open access journal where the Taiwan Society of Anaesthesiologists pays for the publishing costs incurred by the journal. Authors do not have to pay any Article Processing Charge or Open Access Publication Fee. Permitted third party reuse is defined by the following user license: Creative Commons Attribution-NonCommercial-NoDerivs (CC BY-NC-ND)en
dc.titleValidation of the Radford Nomogram to Estimate the Minute Volume Required to Attain Normocapnia in Patients Undergoing General Anesthesia: A Single-Center Retrospective Studyen
dc.typejournal article-
dc.type.niitypeJournal Article-
dc.identifier.jtitleAsian Journal of Anesthesiologyen
dc.identifier.volume57-
dc.identifier.issue3-
dc.identifier.spage101-
dc.identifier.epage108-
dc.relation.doi10.6859/aja.201909_57(3).0005-
dc.textversionpublisher-
dc.addressDepartment of Anesthesia, Kyoto University Hospitalen
dc.addressDepartment of Anesthesia, Kyoto University Hospitalen
dc.addressDepartment of Anesthesia, Kyoto University Hospitalen
dc.addressDepartment of Anesthesia, Kyoto University Hospitalen
dc.addressDepartment of Anesthesia, Kyoto University Hospitalen
dc.addressDepartment of Anesthesia, Kyoto University Hospitalen
dc.addressDepartment of Anesthesia, Kyoto University Hospitalen
dc.identifier.pmid31722508-
dcterms.accessRightsopen access-
datacite.awardNumber16K20092-
datacite.awardNumber17K16728-
dc.identifier.eissn2468-824X-
jpcoar.funderName日本学術振興会ja
jpcoar.funderName日本学術振興会ja
jpcoar.funderName.alternativeJapan Society for the Promotion of Science (JSPS)en
jpcoar.funderName.alternativeJapan Society for the Promotion of Science (JSPS)en
出現コレクション:学術雑誌掲載論文等

アイテムの簡略レコードを表示する

Export to RefWorks


出力フォーマット 


このリポジトリに保管されているアイテムはすべて著作権により保護されています。