このアイテムのアクセス数: 218
このアイテムのファイル:
ファイル | 記述 | サイズ | フォーマット | |
---|---|---|---|---|
s20174826.pdf | 1.03 MB | Adobe PDF | 見る/開く |
完全メタデータレコード
DCフィールド | 値 | 言語 |
---|---|---|
dc.contributor.author | Adachi, Taiki | en |
dc.contributor.author | Kitazumi, Yuki | en |
dc.contributor.author | Shirai, Osamu | en |
dc.contributor.author | Kano, Kenji | en |
dc.contributor.alternative | 足立, 大宜 | ja |
dc.contributor.alternative | 北隅, 優希 | ja |
dc.contributor.alternative | 白井, 理 | ja |
dc.contributor.alternative | 加納, 健司 | ja |
dc.date.accessioned | 2020-10-02T01:11:19Z | - |
dc.date.available | 2020-10-02T01:11:19Z | - |
dc.date.issued | 2020-09-01 | - |
dc.identifier.issn | 1424-8220 | - |
dc.identifier.uri | http://hdl.handle.net/2433/255254 | - |
dc.description.abstract | Bioelectrocatalysis provides the intrinsic catalytic functions of redox enzymes to nonspecific electrode reactions and is the most important and basic concept for electrochemical biosensors. This review starts by describing fundamental characteristics of bioelectrocatalytic reactions in mediated and direct electron transfer types from a theoretical viewpoint and summarizes amperometric biosensors based on multi-enzymatic cascades and for multianalyte detection. The review also introduces prospective aspects of two new concepts of biosensors: mass-transfer-controlled (pseudo)steady-state amperometry at microelectrodes with enhanced enzymatic activity without calibration curves and potentiometric coulometry at enzyme/mediator-immobilized biosensors for absolute determination. | en |
dc.format.mimetype | application/pdf | - |
dc.language.iso | eng | - |
dc.publisher | MDPI AG | en |
dc.rights | © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). | en |
dc.subject | current–potential curve | en |
dc.subject | multi-enzymatic cascades | en |
dc.subject | multianalyte detection | en |
dc.subject | mass-transfer-controlled amperometric response | en |
dc.subject | potentiometric coulometry | en |
dc.title | Development Perspective of Bioelectrocatalysis-Based Biosensors | en |
dc.type | journal article | - |
dc.type.niitype | Journal Article | - |
dc.identifier.jtitle | Sensors | en |
dc.identifier.volume | 20 | - |
dc.identifier.issue | 17 | - |
dc.relation.doi | 10.3390/s20174826 | - |
dc.textversion | publisher | - |
dc.identifier.artnum | 4826 | - |
dc.identifier.pmid | 32858975 | - |
dcterms.accessRights | open access | - |
出現コレクション: | 学術雑誌掲載論文等 |

このリポジトリに保管されているアイテムはすべて著作権により保護されています。