dc.description.abstractObjective: The manual application of hot water or hot metal to an animal's skin surface is often used to prepare burn wound models. However, manual burn creation is subject to human variability.We developed a new device that can control the temperature, time, and pressure of contact to produce precise and reproducible animal burn wounds and investigated the conditions required to prepare various burn wounds using our new device. Methods: We prepared burnwounds on F344 rats using 3 contact times 2, 4, and 10 seconds using a stamp heated to 80C. We observed the wound-healing process macroscopically and histologically and evaluated the burn depth using a laser speckle contrast-imaging device, which evaluated the blood flow of the wound. Results: The changes in the burned area over time, tissue perfusion of the burn wounds, histological evaluation of the burn depth by hematoxylin-eosin and azocarmine and aniline blue staining, and the epithelialization rate (the ratio of the epithelialized area to the wound length) were evaluated on histological sections. Results indicated that the burn wounds prepared with contact times of 2, 4, and 10 seconds corresponded to superficial dermal burns, deep dermal burns, and full-thickness burns, respectively. Conclusions: We demonstrated that partial-and full-thickness burn wounds can be precisely and reproducibly created with our new automated burning device.en
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherLippincott Williams and Wilkinsen
dc.rights© 2016 Wolters Kluwer Health | Lippincott Williams & Wilkins. This is a non-final version of an article published in final form in Annals of Plastic Surgery 2016 Jun;76(6):652-8.en
dc.rightsThis is not the published version. Please cite only the published version. この論文は出版社版でありません。引用の際には出版社版をご確認ご利用ください。en
dc.subjectBurn depthen
dc.subjectBurn depth evaluationen
dc.subjectBurn modelen
dc.subjectBurning deviceen
dc.subjectLaser speckle contrast imaging (FLPI)en
dc.titlePreparation of partial-thickness burn wounds in rodents using a new experimental burning deviceen
dc.typejournal article-
dc.type.niitypeJournal Article-
dc.identifier.jtitleAnnals of Plastic Surgeryen
dc.identifier.volume76-
dc.identifier.spage652-
dc.identifier.epage658-
dc.relation.doi10.1097/SAP.0000000000000655-
dc.textversionauthor-
dc.identifier.pmid27176561-
dc.identifier.kaken24390399-
dcterms.accessRightsopen access-