ダウンロード数: 106
このアイテムのファイル:
ファイル | 記述 | サイズ | フォーマット | |
---|---|---|---|---|
v13020347.pdf | 1.99 MB | Adobe PDF | 見る/開く |
タイトル: | Radioligand Assay-Based Detection of Antibodies against SARS-CoV-2 in Hospital Workers Treating Patients with Severe COVID-19 in Japan. |
著者: | Matsunaga, Hidenori Makino, Akiko https://orcid.org/0000-0001-9628-2126 (unconfirmed) Kato, Yasuhiro Murakami, Teruaki Yamaguchi, Yuta Kumanogoh, Atsushi Oba, Yuichiro Fujimi, Satoshi Honda, Tomoyuki Tomonaga, Keizo https://orcid.org/0000-0003-0405-7103 (unconfirmed) |
著者名の別形: | 松永, 秀典 牧野, 晶子 加藤, 保宏 村上, 輝明 山口, 勇太 熊ノ郷, 淳 大場, 雄一郎 藤見, 聡 本田, 知之 朝長, 啓造 |
キーワード: | SARS-CoV-2 antibody radioligand assay hospital staff low-titer cross reaction |
発行日: | Feb-2021 |
出版者: | MDPI AG |
誌名: | Viruses |
巻: | 13 |
号: | 2 |
論文番号: | 347 |
抄録: | This study aimed to clarify whether infection by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is prevalent among the staff of a hospital providing treatment to patients with severe coronavirus disease 2019 (COVID-19) using radioligand assay (RLA). One thousand samples from the staff of a general hospital providing treatment to patients with severe COVID-19 were assayed for SARS-CoV-2 nucleocapsid protein (N) IgG using RLA. Nine patients with COVID-19 who had been treated in inpatient settings and had already recovered were used as control subjects, and 186 blood donor samples obtained more than 10 years ago were used as negative controls. Four of the 1000 samples showed apparently positive results, and approximately 10 or more samples showed slightly high counts. Interestingly, a few among the blood donor samples also showed slightly high values. To validate the results, antibody examinations using ELISA and neutralizing antibody tests were performed on 21 samples, and chemiluminescence immunoassay (CLIA) was performed on 201 samples, both resulting in a very high correlation. One blood donor sample showed slightly positive results in both RLA and CLIA, suggesting a cross-reaction. This study showed that five months after the pandemic began in Japan, the staff of a general hospital with a tertiary emergency medical facility had an extremely low seroprevalence of the antibodies against SARS-CoV-2. Further investigation will be needed to determine whether the slightly high results were due to cross-reactions or a low titer of anti-SARS-CoV-2 antibodies. The quantitative RLA was considered sensitive enough to detect low titers of antibodies. |
著作権等: | © 2021 by the authors Licensee MDPI, Basel, Switzerland This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license |
URI: | http://hdl.handle.net/2433/262589 |
DOI(出版社版): | 10.3390/v13020347 |
PubMed ID: | 33672213 |
出現コレクション: | 学術雑誌掲載論文等 |
このアイテムは次のライセンスが設定されています: クリエイティブ・コモンズ・ライセンス